2017
DOI: 10.5414/cn109133
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of hemodialysis with medium cut-off dialyzer and on-line hemodiafiltration on the removal of small and middle-sized molecules

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
47
0
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 36 publications
(51 citation statements)
references
References 0 publications
3
47
0
1
Order By: Relevance
“…Hemodialysis with the MCO membranes is associated with albumin loss of approximately 3 g per session (6). In an initial assessment of MCO dialyzers, Belmouaz et al (46) monitored ten patients converted from online HDF to MCO dialysis and did not identify a significant change in serum albumin concentrations, suggesting that this level of albumin loss is tolerable. The REMOVAL-HD Study in Australia and New Zealand is a single-arm, multicenter study designed to specifically address the safety of MCO dialysis (ANZCTRN 12616000804482).…”
Section: Clinical Evaluation Of Mco Dialyzersmentioning
confidence: 99%
“…Hemodialysis with the MCO membranes is associated with albumin loss of approximately 3 g per session (6). In an initial assessment of MCO dialyzers, Belmouaz et al (46) monitored ten patients converted from online HDF to MCO dialysis and did not identify a significant change in serum albumin concentrations, suggesting that this level of albumin loss is tolerable. The REMOVAL-HD Study in Australia and New Zealand is a single-arm, multicenter study designed to specifically address the safety of MCO dialysis (ANZCTRN 12616000804482).…”
Section: Clinical Evaluation Of Mco Dialyzersmentioning
confidence: 99%
“…Existing data on the performance of medium cut-off dialyzers are on the basis of short-term, nonrandomized clinical trials (13)(14)(15)(16)(17)(18)(19). Accordingly, this randomized, controlled trial was conducted to evaluate the efficacy of expanded HD with the Theranova 400 membrane for larger middle molecule removal with acceptable serum albumin loss and safety profile over a 6-month period.…”
Section: Introductionmentioning
confidence: 99%
“…Medium cut-off (MCO) dialyzers can remove middle and large uremic toxins close to the molecular size of albumin (68,000 Da) [11][12][13][14]. MCO dialyzers have been introduced to the dialysis practice as they can perform hemodialysis as efficient as online HDF.…”
Section: Introductionmentioning
confidence: 99%
“…MCO dialyzers have been introduced to the dialysis practice as they can perform hemodialysis as efficient as online HDF. To test this hypothesis, studies were usually performed between hemodialysis with an MCO dialyzer and online HDF with a high-flux dialyzer [12][13][14][15][16][17]. Although global major renal replacement therapy modality is conventional hemodialysis using high-flux dialyzers, there are however relatively few studies comparing MCO and high-flux dialyzers in hemodialysis practice [11,16,18].…”
Section: Introductionmentioning
confidence: 99%