Our system is currently under heavy load due to increased usage. We're actively working on upgrades to improve performance. Thank you for your patience.
2017
DOI: 10.1016/j.vascn.2017.06.001
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of glutathione levels measured using optimized monochlorobimane assay with those from ortho-phthalaldehyde assay in intact cells

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
23
1

Year Published

2018
2018
2024
2024

Publication Types

Select...
9
1

Relationship

1
9

Authors

Journals

citations
Cited by 36 publications
(26 citation statements)
references
References 55 publications
0
23
1
Order By: Relevance
“…Other fluorescent probes, such as monochlorobimane (MCB) and monobromobimane (MBB), used less frequently, also form stable fluorescent adducts with GSH, which can be determined at Ex/Em = 394/490 nm. In comparison with OPA, MCB and MBB have the substantial advantage of penetrating into the cell to react directly with cellular thiols, preventing possible GSH oxidation after cell lysis and allowing analysis by flow cytometry and fluorescence microscopy [158161].…”
Section: Methods and Approaches To Measure Oxidative Stress In CLImentioning
confidence: 99%
“…Other fluorescent probes, such as monochlorobimane (MCB) and monobromobimane (MBB), used less frequently, also form stable fluorescent adducts with GSH, which can be determined at Ex/Em = 394/490 nm. In comparison with OPA, MCB and MBB have the substantial advantage of penetrating into the cell to react directly with cellular thiols, preventing possible GSH oxidation after cell lysis and allowing analysis by flow cytometry and fluorescence microscopy [158161].…”
Section: Methods and Approaches To Measure Oxidative Stress In CLImentioning
confidence: 99%
“…Glutathione levels were measured using the monochlorobimane spectrofluorometric assay 70 . After cell treatment, 20 µL of the bimane solution was added to cells to obtain the final concentration 40 µM and spectrofluorometric measurement was started immediately.…”
Section: Methodsmentioning
confidence: 99%
“…Glutathione levels were measured using the monochlorobimane spectro uorometric assay 67 . After cell treatment, 20 µL of the bimane solution was added to cells to obtain the nal concentration 40 µM and spectro uorometric measurement was started immediately.…”
Section: Glutathione Assaymentioning
confidence: 99%