2021
DOI: 10.1016/j.ijcard.2020.08.070
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of fluoroscopy and transesophageal echocardiogram for intra-procedure device surveillance assessment during implantation of Watchman

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

6
30
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 20 publications
(42 citation statements)
references
References 24 publications
6
30
1
Order By: Relevance
“…They reported the optimistic results with a 100% implantation success rate (31/31), 0 events of peri‐procedural complications, no significant peri‐device leakage (>5 mm), no DRT, 0 events of ischemic stroke during 3–45 months follow‐up. In the present study, the procedure time, fluoroscopy time, total radiation dose, contrast medium dose, percentage of fluoroscopic peri‐device leakage is similar to the previous reports of the variable devices implanted under procedural fluoroscopic guidance only 6,16,17 or the LAmbre device implantation guided by TEE 26 . The cost for each patient, about 58,000 yuan (8900 USD) in our institution, was less than the previous report 17 .…”
Section: Discussionsupporting
confidence: 86%
See 4 more Smart Citations
“…They reported the optimistic results with a 100% implantation success rate (31/31), 0 events of peri‐procedural complications, no significant peri‐device leakage (>5 mm), no DRT, 0 events of ischemic stroke during 3–45 months follow‐up. In the present study, the procedure time, fluoroscopy time, total radiation dose, contrast medium dose, percentage of fluoroscopic peri‐device leakage is similar to the previous reports of the variable devices implanted under procedural fluoroscopic guidance only 6,16,17 or the LAmbre device implantation guided by TEE 26 . The cost for each patient, about 58,000 yuan (8900 USD) in our institution, was less than the previous report 17 .…”
Section: Discussionsupporting
confidence: 86%
“…In the present study, the procedure time, fluoroscopy time, total radiation dose, contrast medium dose, percentage of fluoroscopic peri‐device leakage is similar to the previous reports of the variable devices implanted under procedural fluoroscopic guidance only 6,16,17 or the LAmbre device implantation guided by TEE 26 . The cost for each patient, about 58,000 yuan (8900 USD) in our institution, was less than the previous report 17 . The favorable procedural characteristics could be owed to the operators’ experience and skill in radiofrequency ablation for operators.…”
Section: Discussionsupporting
confidence: 86%
See 3 more Smart Citations