Comparison of Five Cone Beam Computed Tomography Systems for the Detection of Vertical Root Fractures

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

7
137
2
16

Year Published

2012
2012
2022
2022

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 161 publications
(170 citation statements)
references
References 32 publications
7
137
2
16
Order By: Relevance
“…Gray values obtained with CBCT are used in an analog way as the HU values for the determination of mineral density [16] and show a linear relationship with the attenuation coefficients of the materials [13,15] , HU values obtained with medical CT [11,12,37,38] , and density values from DEXA [14] . Despite the correlation between gray values obtained with MSCT and CBCT, errors are expected when CBCT images are used to define the density of scanned structures [39] because these images present with inconsistencies and arbitrariness of gray values [16,40] , especially when related to abrupt changes of density in the object [41,42] , X-ray beam hardening effect [39,43] , scattered radiation [43] and projection data discontinuity-related effect [16] , making the validity of the measurements obtained questionable (Table 1).…”
Section: Cone Beam Ctmentioning
confidence: 99%
“…Gray values obtained with CBCT are used in an analog way as the HU values for the determination of mineral density [16] and show a linear relationship with the attenuation coefficients of the materials [13,15] , HU values obtained with medical CT [11,12,37,38] , and density values from DEXA [14] . Despite the correlation between gray values obtained with MSCT and CBCT, errors are expected when CBCT images are used to define the density of scanned structures [39] because these images present with inconsistencies and arbitrariness of gray values [16,40] , especially when related to abrupt changes of density in the object [41,42] , X-ray beam hardening effect [39,43] , scattered radiation [43] and projection data discontinuity-related effect [16] , making the validity of the measurements obtained questionable (Table 1).…”
Section: Cone Beam Ctmentioning
confidence: 99%
“…The accuracy of CBCT for detection of VRFs also appears to be dependent on the CBCT device used. Several studies have assessed different CBCT scanners and found varying degrees of diagnostic accuracy for detecting simulated VRFs (16). The quality of CBCT scans, their contrast and resolution depend on the detector type, size of FOV, voxel size, artifact level and the amount of basic images and algorithm of scan reconstruction (16).…”
Section: Discussionmentioning
confidence: 99%
“…Several studies have assessed different CBCT scanners and found varying degrees of diagnostic accuracy for detecting simulated VRFs (16). The quality of CBCT scans, their contrast and resolution depend on the detector type, size of FOV, voxel size, artifact level and the amount of basic images and algorithm of scan reconstruction (16). The difference between the sensitivity of CBCT device obtained in the present study and that of previous studies may be due to the type of detector, detector sensitivity, exposure parameters, voxel settings and reconstruction algorithms of the assessed CBCT scanners (16).…”
Section: Discussionmentioning
confidence: 99%
“…During the image analysis, the examiners were able to use all the available program resources (different reconstruction plans, zoom, brilliance, contrast, and filters) with no time limit. Using a table, the examiners recorded their reports of presence or absence of fracture 8,10,[18][19][20] and, in positive cases of fracture, the location of the fracture was determined (cervical, middle, or apical third).…”
Section: Tomographic Analysismentioning
confidence: 99%