2019
DOI: 10.2214/ajr.18.20239
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of End-Expiration Versus End-Inspiration Breath-Holds With Respect to Respiratory Motion Artifacts on T1-Weighted Abdominal MRI

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
14
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 16 publications
(14 citation statements)
references
References 26 publications
0
14
0
Order By: Relevance
“…A 32-channel body coil with digital interface was used for signal reception. Besides morphological sequences, hepatic T1 mapping before and 10 min after contrast media application was performed in the same slice position in end-expiration 19 . For T1 mapping, a heart rate independent 10-(2)-7-(2)-5-(2)-3-(2) modified Look-Locker inversion recovery (MOLLI) acquisition scheme with internal triggering was applied.…”
Section: Methodsmentioning
confidence: 99%
“…A 32-channel body coil with digital interface was used for signal reception. Besides morphological sequences, hepatic T1 mapping before and 10 min after contrast media application was performed in the same slice position in end-expiration 19 . For T1 mapping, a heart rate independent 10-(2)-7-(2)-5-(2)-3-(2) modified Look-Locker inversion recovery (MOLLI) acquisition scheme with internal triggering was applied.…”
Section: Methodsmentioning
confidence: 99%
“…Breath holding can be performed at end-expiration and inspiration with protocols developed according to local expertise. In a study relating to T1 Abdominal/Hepatic MRI, Vu et al demonstrated a significant reduction in motion-related artifacts with end-expiration compared to end-inspiration in contrast-enhanced and unenhanced sequences [ 61 ]. Future studies assessing end-inspiration in MRE to determine its impact on motion artifacts and subsequent CD activity assessment are needed.…”
Section: Motion Artifactmentioning
confidence: 99%
“…Cardiac MRI can be performed at either end-expiration or end-inspiration. In both of these respiratory phases susceptibility artifacts can be seen ( Table II ), while their location is shifted towards the apex at the end-inspiration phase [ 16 ]. The end-expiration leads to a significant decrease of respiratory motion artifacts [ 16 ] and is more pronounced due to the higher reproducibility [ 17 ].…”
Section: Development Of Dti Of the Heart In Vivomentioning
confidence: 99%