2021
DOI: 10.1111/anec.12872
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of electrocardiograms (ECG) waveforms and centralized ECG measurements between a simple 6‐lead mobile ECG device and a standard 12‐lead ECG

Abstract: Background: Interval duration measurements (IDMs) were compared between standard 12-lead electrocardiograms (ECGs) and 6-lead ECGs recorded with AliveCor's KardiaMobile 6L, a hand-held mobile device designed for use by patients at home. Methods: Electrocardiograms were recorded within, on average, 15 min from 705 patients in Mayo Clinic's Windland Smith Rice Genetic Heart Rhythm Clinic. Interpretable 12-lead and 6-lead recordings were available for 685 out of 705 (97%) eligible patients. The most common diagno… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
36
0
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(37 citation statements)
references
References 9 publications
0
36
0
1
Order By: Relevance
“…This device has three electrodes that allow simultaneous recordings of all limbs leads by holding the device with both hands and applying the rear electrode against the left leg, and for this device, mean ECG interval duration measurements have been demonstrated to be comparable to supine standard 12-lead ECGs. 22 …”
Section: Discussionmentioning
confidence: 99%
“…This device has three electrodes that allow simultaneous recordings of all limbs leads by holding the device with both hands and applying the rear electrode against the left leg, and for this device, mean ECG interval duration measurements have been demonstrated to be comparable to supine standard 12-lead ECGs. 22 …”
Section: Discussionmentioning
confidence: 99%
“…The BIA method is widely used in research that uses body fat monitors to quickly determine body composition. Instead, the portable ECG with six leads, with smartphone applications, has recently appeared on the market and has been less used for studies on the electrical intervals of the heart [ 34 ]. Moreover, the use of both types of assessment for the assumed objectives of the research is a novelty.…”
Section: Discussionmentioning
confidence: 99%
“…Several companies have proposed portable ECG devices with a smartphone interface that allow simultaneous recording on six leads. Preliminary data indicate that the measured electrical intervals are close enough to allow the detection of clinically meaningful abnormalities [ 34 ]. These devices have good accuracy for reliable QT and QTc interval determination and, therefore, can be used in clinical trials [ 35 ].…”
Section: Introductionmentioning
confidence: 99%
“…Es konnten eine Sensitivität von 98,5 % und eine Spezifität von 91,4 % gezeigt werden [21]. Durch Erweiterung um eine dritte Elektrode auf der Rückseite der Platte, die auf das linke Bein aufgelegt wird, kann ein 6-Kanal-EKG abgeleitet werden [20].…”
Section: Ekg-basierte Anwendungenunclassified