2010 3rd International Conference on Emerging Trends in Engineering and Technology 2010
DOI: 10.1109/icetet.2010.47
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of Double Loop, Direct-Output-Voltage and Fuzzy-PI Control Strategies for D-STATCOM

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
2
2

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(6 citation statements)
references
References 9 publications
0
3
0
Order By: Relevance
“…First loop was used to keep the DC capacitor constant, while the second loop were used to extract the reference source currents [36]. Second, the type I fuzzy logic were used as an adjuster to tune the PI controller in the double-loop control strategy [37]. Third, the fuzzy logic controller used to change the proportional and integration gains in the respect of the load changing instantaneously.…”
Section: Review Of Literaturementioning
confidence: 99%
See 1 more Smart Citation
“…First loop was used to keep the DC capacitor constant, while the second loop were used to extract the reference source currents [36]. Second, the type I fuzzy logic were used as an adjuster to tune the PI controller in the double-loop control strategy [37]. Third, the fuzzy logic controller used to change the proportional and integration gains in the respect of the load changing instantaneously.…”
Section: Review Of Literaturementioning
confidence: 99%
“…A fuzzy logic controller was applied to control the active power filter and compared with neuro-fuzzy logic controller [41]. After the application of the type I fuzzy logic the researcher started to face the uncertainty problem which is considered as one of type I fuzzy logic drawbacks [37].…”
Section: Review Of Literaturementioning
confidence: 99%
“…Mehtn and Schauder [7]presented a Conventional Double-Loop Control Strategy. In this method, there are two loops; the external loop of the active and reactive current generates the reference current for maintaining the voltage at the PCC point, and the internal loop is used to control the inverter current [8].…”
Section: Introductionmentioning
confidence: 99%
“…These equations are transmitted using the park transformation to the d-q axis, on which the voltage of the PCC point corresponds to that of the d-axis, and the q-axis is perpendicular to the d-axis:By inserting Eqs. (4),(5) and(8) in Eq. (3), the following equation is obtained:…”
mentioning
confidence: 99%
“…In [18], investigated and implemented the Fuzzy-PI control of DSTATCOM based on the double-loop control strategy. A fuzzy adjuster was added to tune the parameters of the PI controllers.…”
mentioning
confidence: 99%