Comparison of different functional EIT approaches to quantify tidal ventilation distribution

Abstract: The analysis software provided by the currently available commercial EIT equipment only offers either fEIT of standard deviation or tidal variation. Considering the pros and cons of each fEIT type, we recommend embedding more types into the analysis software to allow the physicians dealing with more complex clinical applications with on-line EIT measurements.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
16
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
5
1

Relationship

4
2

Authors

Journals

citations
Cited by 22 publications
(17 citation statements)
references
References 26 publications
0
16
0
Order By: Relevance
“…changes of skin condition, electrode position, thorax shape etc., baseline drift would be induced. Care should be taken when interpreting continuous long term EIT data, since some of the standard functional EITs would not be valid [5]. Although EIT has the potential to detect patient-ventilator asynchrony, diseases progression and to evaluate treatment efficiency, up to now there are no systematic studies exploring the feasibility and validity of long term EIT monitoring.…”
Section: Discussion and Future Workmentioning
confidence: 99%
See 3 more Smart Citations
“…changes of skin condition, electrode position, thorax shape etc., baseline drift would be induced. Care should be taken when interpreting continuous long term EIT data, since some of the standard functional EITs would not be valid [5]. Although EIT has the potential to detect patient-ventilator asynchrony, diseases progression and to evaluate treatment efficiency, up to now there are no systematic studies exploring the feasibility and validity of long term EIT monitoring.…”
Section: Discussion and Future Workmentioning
confidence: 99%
“…According to the current injection and reconstruction principles, EIT can be categorized to absolute EIT [14,15] and difference EIT (including frequency-difference [3,4] and timedifference EIT [5,6]). Due to technical difficulties, only time-difference EIT is used in current commercial EIT devices and clinical applications [143].…”
Section: Clinical Applications Of Time-difference Eitmentioning
confidence: 99%
See 2 more Smart Citations
“…EIT data analysis was achieved using customized software developed with MATLAB (R2015a; MathWorks). Functional ventilation map was derived from averaging the tidal impedance variation images ( 8 ). Functional perfusion map was calculated as the slope of regional impedance–time curves after saline bolus injection ( 7 ).…”
Section: Methodsmentioning
confidence: 99%