2019
DOI: 10.1016/j.ijsu.2019.09.001
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of cyanoacrylate and hookwire for localizing small pulmonary nodules: A propensity-matched cohort study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
12
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 10 publications
(12 citation statements)
references
References 21 publications
0
12
0
Order By: Relevance
“…Both solid and liquid materials, such as hookwires, 9‐14 lipiodol, 15 microcoils, 12,16,17 dye 17,18 and radiotracers 19 have been developed as localization markers. We summarized the literature on preoperative localization techniques with sample numbers >100 and other similar studies published within the last five years, 11,20‐25 and compared the results with ours (Table 4 ) . Although these methods have been applied widely in clinical practice and reported favorable results, they reveal some shortcomings.…”
Section: Discussionmentioning
confidence: 99%
“…Both solid and liquid materials, such as hookwires, 9‐14 lipiodol, 15 microcoils, 12,16,17 dye 17,18 and radiotracers 19 have been developed as localization markers. We summarized the literature on preoperative localization techniques with sample numbers >100 and other similar studies published within the last five years, 11,20‐25 and compared the results with ours (Table 4 ) . Although these methods have been applied widely in clinical practice and reported favorable results, they reveal some shortcomings.…”
Section: Discussionmentioning
confidence: 99%
“…Some areas of the lung were deemed difficult zones (24.9%) for POCTGL, which included traditional "danger zones" including the mediastinum (15.4%), diaphragm (10.5%), and structures in the path of the puncture, including scapula (5.2%), breast prosthesis (0.3%), and the structures associated with pleura comprising fissure (7.5%) and cross-lobe (3.4%). The median size of the pulmonary nodules receiving POCTGL was 5 (2)(3)(4)(5)(6)(7)(8)(9)(10)(11)(12)(13)(14)(15)(16)(17)(18)(19) mm. The median puncture angle was 19 0 .…”
Section: Demography and Performance Of The Preoperative Ct Guided Loc...mentioning
confidence: 99%
“…However, due to the small size of the nodules, preoperative localization methods are warranted and have rapidly emerged 4–9 . Percutaneous CT‐guided localization with a dye, hookwire, coils, or radioisotopes is the most popular adopted method 5,9–12 . Other approaches, including the navigator, three‐dimensional pulmonary reconstruction, and augmented fluoroscopic bronchoscopy, have also been implemented 8,13 …”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations