2015
DOI: 10.2147/opth.s88225
|View full text |Cite|
|
Sign up to set email alerts
|

Comparison of cumulative dissipated energy between the Infiniti and Centurion phacoemulsification systems

Abstract: PurposeTo compare cumulative dissipated energy between two phacoemulsification machines.SettingAn ambulatory surgical center, Honolulu, Hawaii, USA.DesignRetrospective chart review.MethodsA total of 2,077 consecutive cases of cataract extraction by phacoemulsification performed by five surgeons from November 2012 to November 2014 were included in the study; 1,021 consecutive cases were performed using the Infiniti Vision System, followed by 1,056 consecutive cases performed using the Centurion Vision System.Re… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
43
0
6

Year Published

2017
2017
2020
2020

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 47 publications
(49 citation statements)
references
References 11 publications
0
43
0
6
Order By: Relevance
“…For this reason, it would be highly desirable for different phacoemulsification machines to declare tip actual or at least nominal elongation, as the absence of such information makes any comparison impossible. 8,[11][12][13][14][15] In summary, our data demonstrate that actual tip elongation may differ as much as 60% in the absence of a feedback control mechanism that could significantly improve tip elongation accuracy regardless of resistance. Tip elongation consistency improves efficiency by reducing US energy dispersion.…”
Section: Discussionmentioning
confidence: 71%
“…For this reason, it would be highly desirable for different phacoemulsification machines to declare tip actual or at least nominal elongation, as the absence of such information makes any comparison impossible. 8,[11][12][13][14][15] In summary, our data demonstrate that actual tip elongation may differ as much as 60% in the absence of a feedback control mechanism that could significantly improve tip elongation accuracy regardless of resistance. Tip elongation consistency improves efficiency by reducing US energy dispersion.…”
Section: Discussionmentioning
confidence: 71%
“…An attempt was made to use more stable modalities like an air pump or pressurised irrigation bottle with gas with some benefits. However, as the gas infusion pressure does not necessarily vary in response to the changing aspiration flow rate, the effect is the same as raising the bottle height [ 4 , 11 ]. More recent machines maintain IOP by using a compliant irrigation bag, which is squeezed in response to the aspiration flow rate and estimated incision leakage.…”
Section: Discussionmentioning
confidence: 99%
“…More recent machines maintain IOP by using a compliant irrigation bag, which is squeezed in response to the aspiration flow rate and estimated incision leakage. Centurion uses an Active Fluidics Technology as compared to a gravity fed infusion system in the Infiniti [ 4 ].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…der kumulativen Energie. Der geringere Flüssigkeitsverbrauch soll auch das Endothel schützen [3,4]. Beim Ver- gleich der unterschiedlichen Phakohandgriffspitzen Kelman Tipp und Balanced Tipp konnte bei der mikrokoaxialen torsionalen Phakoemulsifikation kein Unterschied im Endothelzellverlust gezeigt werden [15], jedoch wurde die gleiche Flüssigkeitssteuerung verwendet und nicht auf den Unterschied der aktiven und der standardisierten Flüssigkeitssteuerung eingegangen.…”
Section: Diskussionunclassified