2008
DOI: 10.1007/s10384-008-0550-x
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of central corneal thickness measurements by Orbscan II and Pentacam after corneal refractive surgery

Abstract: The Orbscan II measurement values of postoperative corneas tended to be thinner than the theoretical values, but not those of the Pentacam.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
13
0
3

Year Published

2010
2010
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 25 publications
(17 citation statements)
references
References 30 publications
(44 reference statements)
1
13
0
3
Order By: Relevance
“…For both rotating Scheimpflug imaging and FD-OCT, they calculated the distance between the anterior and posterior corneal surfaces and transformed it into corneal pachymetry. These two systems yield highly reliable measurements of corneal thickness in healthy eyes, 17)20, 47 although they can be affected if the cornea is not clear or if there is other optical interference (Matsuda et al 2008). The differences we and others report between the optical methods and UP in different research settings may be mainly attributed to sources of measurement variability inherent in UP itself.…”
Section: Discussionmentioning
confidence: 99%
“…For both rotating Scheimpflug imaging and FD-OCT, they calculated the distance between the anterior and posterior corneal surfaces and transformed it into corneal pachymetry. These two systems yield highly reliable measurements of corneal thickness in healthy eyes, 17)20, 47 although they can be affected if the cornea is not clear or if there is other optical interference (Matsuda et al 2008). The differences we and others report between the optical methods and UP in different research settings may be mainly attributed to sources of measurement variability inherent in UP itself.…”
Section: Discussionmentioning
confidence: 99%
“…Kor ne a cer ra hi le rin de ame li yat ön ce si, ame li yat es na sında ve ame li yat son ra sında mer ke zi kor ne a ka lın lı ğı-nın (MKK) de ğer len di ril me si, [1][2][3][4] kon takt lens kulla nı cı la rın da kor ne a sağ lı ğı nın ve de ği şik lik le ri nin ta ki bi 5,6 ile glo ko mun ta nı ve te da vi si gi bi bir çok kli nik du rum da MKK önem li bir gös ter ge dir. [7][8][9][10] Gü nü müz de MKK öl çü mün de al tın stan dart ola rak ka bul edi len ve dün ya ça pın da yay gın bir biçim de kul la nı lan me tod ul tra so nik pa ki met re dir.…”
Section: Ophthalmologyunclassified
“…Do la yı sıy la iş le mi ger çek leş tiren tek nis ye nin tec rü be si, ul tra so nik pa ki met ri le ri so nuç la rı nı et ki le ye bil mek te dir. 2,3,5 Ul tra so nik bi yo mik ros ko pi (UBM), yük sek fre kans lı ses dal ga la rı nın kul la nı mıy la gö zün ön seg men ti ne ait ke sit sel gö rün tü le rin el de edil di ği de ğer li bir gö rün tü le me yön te mi dir. Bu tek nik le ön seg men te ait bir çok mor fo lo jik ve pa to lo jik özel lik ya nın da [11][12][13][14] MKK öl çü mü de ya pı la bil mek te dir.…”
Section: Ophthalmologyunclassified
See 1 more Smart Citation
“…the Orbscan measures being less than those obtained by US. [89] On the other hand, AF of 0.92 has been reported to overestimate CCT in the thickest extreme of corneas. [510]…”
Section: Introductionmentioning
confidence: 99%