Comparison of Burst, Pulse, and Linear Modes Used in Phacoemulsification Surgery

Abstract: Phacoemulsification power should be kept at minimum in order to induce minimal trauma and to achieve early rehabilitation.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
9
0
1

Year Published

2011
2011
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(10 citation statements)
references
References 31 publications
0
9
0
1
Order By: Relevance
“…€ Ozkurt et al 17 report that the CCT was significantly higher in a pulse-mode group than in a burstmode group at 1 day and 1 week, whereas there were no significant differences between the pulse and continuous modes and between the burst and continuous modes. € Ozkurt et al 17 report that the increased CCT in pulse mode was associated with the higher US power.…”
Section: Discussionmentioning
confidence: 94%
See 1 more Smart Citation
“…€ Ozkurt et al 17 report that the CCT was significantly higher in a pulse-mode group than in a burstmode group at 1 day and 1 week, whereas there were no significant differences between the pulse and continuous modes and between the burst and continuous modes. € Ozkurt et al 17 report that the increased CCT in pulse mode was associated with the higher US power.…”
Section: Discussionmentioning
confidence: 94%
“…€ Ozkurt et al 17 report that the CCT was significantly higher in a pulse-mode group than in a burstmode group at 1 day and 1 week, whereas there were no significant differences between the pulse and continuous modes and between the burst and continuous modes. € Ozkurt et al 17 report that the increased CCT in pulse mode was associated with the higher US power. 17 Braga-Mele et al 18 found that temperature rises occurred under pulse mode in nucleus occlusion and that phacoemulsification with a sleeveless needle through a small stab incision could be safely performed with the Millennium system (Bausch & Lomb Surgical) using conventional phaco burst-mode settings and certain parameters.…”
Section: Discussionmentioning
confidence: 94%
“…[21] In addition, burst ultrasound mode can reduce the overall ultrasound energy, as evidenced by less mean CDE, and the effective UST in the torsional and burst mode compared with the conventional mode. As high ultrasound energy is associated with increased damage to corneal endothelial cells, [4] the lower energy used in torsional and burst mode may contribute to less corneal endothelial cell injury. Our findings are consistent with the previous reports that the torsional burst phacoemulsification mode was associated with greater safety and less damage to the corneal endothelial cells compared with the conventional phacoemulsification mode.…”
Section: Discussionmentioning
confidence: 99%
“…Damage of the corneal endothelial cells during cataract surgery positively correlates with the power and time of ultrasound. [4] Burst ultrasound mode can reduce the overall ultrasound energy by reducing the mean CDE and the effective UST. Therefore, the combined torsional and burst mode has better efficiency than the conventional mode, and damage to the surrounding ocular tissue is less.…”
Section: Discussionmentioning
confidence: 99%
“…Hemos encontrado una correlación directa entre la cantidad de edema corneal y estos dos parámetros, como ya se había observado previamente 108 . Sin embargo, no existe una correlación entre estos dos parámetros y la refracción final, tanto esférica como cilíndrica ni tampoco con la estabilización refractiva o paquimétrica.…”
Section: 33-factores Que Influyen En La Refracciónunclassified