2002
DOI: 10.1186/cc1848
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of bedside measurement of cardiac output with the thermodilution method and the Fick method in mechanically ventilated patients

Abstract: Introduction Bedside cardiac output determination is a common preoccupation in the critically ill. All available methods have drawbacks. We wished to re-examine the agreement between cardiac output determined using the thermodilution method (QTTHERM) and cardiac output determined using the metabolic (Fick) method (QTFICK) in patients with extremely severe states, all the more so in the context of changing practices in the management of patients. Indeed, the interchangeability of the methods is a clinically rel… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0

Year Published

2009
2009
2020
2020

Publication Types

Select...
8
2

Relationship

1
9

Authors

Journals

citations
Cited by 37 publications
(11 citation statements)
references
References 37 publications
(57 reference statements)
0
7
0
Order By: Relevance
“…In vigorously breathing neonates, the variation was as high as 40% (as indicated by the Aesculon® monitor). The variation in stroke volume during the respiratory cycle is a problem for any method of determining CO [26,30,36,37]. Theoretically, variation in stroke volume should equally affect EV and TTE.…”
Section: Discussionmentioning
confidence: 99%
“…In vigorously breathing neonates, the variation was as high as 40% (as indicated by the Aesculon® monitor). The variation in stroke volume during the respiratory cycle is a problem for any method of determining CO [26,30,36,37]. Theoretically, variation in stroke volume should equally affect EV and TTE.…”
Section: Discussionmentioning
confidence: 99%
“…Many authors compare the results of CO measurements obtained by means of the thermodilution and the Fick methods [6][7][8][9][10][11][12][13][14] but in fact, the accuracies of the others methods are unknown. Therefore only the correlation of results may be estimated.…”
Section: Introductionmentioning
confidence: 99%
“…PAC thermodilution method could be considered the current clinical standard and is commonly used to validate new CO measurement methods [4, 1920, 24]. We chose the pediatric post heart transplant patient population undergoing hemodynamic evaluation in our catheterization laboratory primarily because all these patients have a PAC catheter and a central venous and arterial catheter placed irrespective of this study.…”
Section: Discussionmentioning
confidence: 99%