1975
DOI: 10.1016/0009-8981(75)90104-7
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of an all-aqueous automated urine pregnancy oestrogen method with one using organic solvent extraction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

1976
1976
1983
1983

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(3 citation statements)
references
References 8 publications
0
3
0
Order By: Relevance
“…Some authors (Shelley et al 1970;Powers and Roach 1974) have suggested that oestrogen/creatinine ratios could be used to overcome the diurnal vari¬ ations, but the results have not been convincing. Recently, auto¬ matic procedures with a high precision and clinical reliability have been reported (Moscrop et al 1974;Little et al 1975). Up to now the majority of results reported in the literature have been obtained by methods involving hydrolysis of urine, extraction and separation of the phenolic fraction, and colorimetry, photometry, fluorometry or gas-liquid chromatography.…”
Section: Metabolism Of Oestrogens In Pregnancymentioning
confidence: 99%
“…Some authors (Shelley et al 1970;Powers and Roach 1974) have suggested that oestrogen/creatinine ratios could be used to overcome the diurnal vari¬ ations, but the results have not been convincing. Recently, auto¬ matic procedures with a high precision and clinical reliability have been reported (Moscrop et al 1974;Little et al 1975). Up to now the majority of results reported in the literature have been obtained by methods involving hydrolysis of urine, extraction and separation of the phenolic fraction, and colorimetry, photometry, fluorometry or gas-liquid chromatography.…”
Section: Metabolism Of Oestrogens In Pregnancymentioning
confidence: 99%
“…The most recent developments are based on the performance of KOBER color reaction directly on urine followed by ITTRICH extraction and fluorimetry [15]. This permits the use of automated, continuous-flow Systems which allow up to 70 or more samples to be assayed each day with a high degree of precision [71,88] and clinicäl reliability [51 ]. It also seems to be the most accurate method, in terms of precision between different laboratories [91].…”
Section: Urinary Estrogen Determinationsmentioning
confidence: 99%
“…Urinary total oestrogens (pmol/l) and creatinine (mmol/l) were measured by combining an all-aqueous automated continuous flow method for oestrogens (Little et al, 1975) with simultaneous measurement of creatinine. Data were transformed to log,, for calculation of the OjC ratio to facilitate comparison of values throughout the reference range (Phillips et al, 1978).…”
mentioning