Comparison of Air Temperature Calibrations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
6
0
1

Year Published

2015
2015
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 2 publications
0
6
0
1
Order By: Relevance
“…One area of special concern is where two thermometers are compared during calibration. Heinonen [11] has already highlighted the problem of sensors with different emissivities, but this work shows that differences in sensor diameters can also lead to errors where a thin sensor 'inherits' the larger radiation error from a larger calibrated sensor.…”
Section: Precision Measurement In Generalmentioning
confidence: 94%
See 2 more Smart Citations
“…One area of special concern is where two thermometers are compared during calibration. Heinonen [11] has already highlighted the problem of sensors with different emissivities, but this work shows that differences in sensor diameters can also lead to errors where a thin sensor 'inherits' the larger radiation error from a larger calibrated sensor.…”
Section: Precision Measurement In Generalmentioning
confidence: 94%
“…In a comparison of air temperature calibration procedures, Heinonen et al [11] record the diameter of the probes used, deliberately use probes with different emissivities, and analyse their results to study the effects of emissivity. However, they do not analyse the dependence of radiative errors on diameter.…”
Section: Metrologymentioning
confidence: 99%
See 1 more Smart Citation
“…The laboratory was equipped with a two-pressure humidity generator, cooled mirror dew-point meters, a climatic chamber, and hygrometers to perform calibrations from 11 %rh to 95 %rh in an air temperature range from −10 • C to 70 • C, which also covers the dew-point range from −35 • C to 65 • C. The capability of the laboratory was extended down to −60 • C in the dew-point temperature range with the construction of a two-temperature humidity generator in cooperation with MIKES in 2013. The laboratory participated in EURAMET comparison programs in order to assess its technical performance internationally where the final reports can also be found on the EURAMET web site [5][6][7].…”
Section: Introductionmentioning
confidence: 99%
“…(Žužek & Pušnik, 2017;van Geel, Bosma, van Wensveen, & Peruzzi, 2015; (DKD, 2004) (Engineers, 2003). Akan tetapi fasilitas yang digunakan di dalam contoh masingmasing dokumen sangat mahal yaitu menggunakan sensor suhu Pt-100 (Heinonen, et al, 2014)…”
unclassified