2013
DOI: 10.1016/j.enbuild.2012.10.053
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of air change efficiency, contaminant removal effectiveness and infection risk as IAQ indices in isolation rooms

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

3
48
1

Year Published

2013
2013
2024
2024

Publication Types

Select...
7
2
1

Relationship

0
10

Authors

Journals

citations
Cited by 75 publications
(52 citation statements)
references
References 26 publications
3
48
1
Order By: Relevance
“…The results obtained by the investigation presented in this paper support the statement that the position of the air inlets and outlets has a great influence on the quality of the ventilation (when the rest of the parameters are equal) [30].…”
Section: Discussionsupporting
confidence: 88%
“…The results obtained by the investigation presented in this paper support the statement that the position of the air inlets and outlets has a great influence on the quality of the ventilation (when the rest of the parameters are equal) [30].…”
Section: Discussionsupporting
confidence: 88%
“…The ventilation strategy usually provides as much clean air as possible for the breathing zone by both diluting the pollutants and infected air from the indoor environment and removing the pollutants and infected air from it (Etheridge and Sandberg 1996;Awbi 2003). Although a lot of studies have been conducted to minimize the airborne infection routes in healthcare settings by using engineering solutions (Cheong and Phua, 2006;Qian et al 2008;Kwan et al 2008;Ho et al 2009;Nielsen et al 2010;Yam et al 2011;Villafruela et al 2013), only specialized areas, such as wards, operating rooms, and isolation rooms, were considered.…”
Section: Introductionmentioning
confidence: 98%
“…To prevent or minimize the spread of contaminated air exhaled by occupants efficiently, the ideal strategy is to exhaust the exhaled air as much as possible right around the IP. In the field of ventilation design in healthcare centers and hospitals, many studies have been conducted to minimize both the short-range and long-range airborne infection routes (Baloccoa and Lio, 2011;Cheong and Phua, 2006;Ho et al, 2009;Nielsen et al, 2010;Qian et al, 2008;Villafruela et al, 2013). However, most healthcare ventilation system studies focus on specialized areas such as ward, operating rooms, and isolation rooms.…”
Section: Introductionmentioning
confidence: 99%