2022
DOI: 10.1186/s12886-021-02217-6
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of accommodation and accommodative micro-fluctuation after implantable collamer lens and LASIK surgery for myopia

Abstract: Background To longitudinally analyze and compare the accommodative micro-fluctuation (MFs) and accommodative function between myopic patients after implantable collamer lens (ICL) implantation and laser in situ keratomileusis (LASIK). Methods Patients with good corrected visual acuity (20/20 or better) and underwent ICL (V4c) and LASIK for myopic-correction (ranging from − 3.50 to − 8.50 D) were recruited. Refraction, amplitude of accommodation (AM… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 29 publications
0
4
0
Order By: Relevance
“…e integrity of tear film can affect higher-order aberration, and the unsmooth anterior corneal surface induced by tear film destruction is the key factor leading to the increase of HOAs [20][21][22][23][24]. Pupil diameter changes [25][26][27][28] and adjustments [29][30][31][32][33] can also cause changes in HOAs. erefore, we used fixed targets in our instruments and designed to control the patient's pupil diameter to eliminate the effect on HOAs measurement.…”
Section: Discussionmentioning
confidence: 99%
“…e integrity of tear film can affect higher-order aberration, and the unsmooth anterior corneal surface induced by tear film destruction is the key factor leading to the increase of HOAs [20][21][22][23][24]. Pupil diameter changes [25][26][27][28] and adjustments [29][30][31][32][33] can also cause changes in HOAs. erefore, we used fixed targets in our instruments and designed to control the patient's pupil diameter to eliminate the effect on HOAs measurement.…”
Section: Discussionmentioning
confidence: 99%
“…OPD Scan III is an aberrometer with Placido based on a shack Hartmann. The study of aberration using OPD Scan III has been applied in previous studies and has clinical significance, including studies in the 4 mm area [8][9] , with the help of Fourier transform, OQAS is designed according to the asymmetric pattern of the double-pass technology [10] . It is currently the only instrument that can be used to objectively measure the optimal aberration and the impact of human eye transparency loss.…”
Section: Ethical Approvalmentioning
confidence: 99%
“…В ранее проведенных исследованиях сообщалось о нарушениях аккомодационной и (или) бинокулярной функции глаза, связанных с послеоперационной анизометропией и роговичными осложнениями [6], однако в нашей работе данные факторы являлись критериями исключения пациентов из исследования. Более четкое и сопоставимое с представленными результатами настоящего исследования заключение было сформулировано в работах авторов, которые утверждают, что проведение ЛАСИК не оказывает существенного влияния на аккомодацию, при этом выявленные послеоперационные нарушения были диагностированы в рамках предоперационного обследования [24][25][26].…”
Section: результатыunclassified