SEG Technical Program Expanded Abstracts 2011 2011
DOI: 10.1190/1.3627576
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of a vertical electric and a vertical magnetic source for cross well CSEM monitoring of CO 2 injection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2012
2012
2021
2021

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 9 publications
0
4
0
Order By: Relevance
“…Given the sensitivity differences that VMD and VED systems exhibit for resistive targets (Harris and Pethick, 2011;Grayver and Streich, 2014), an important question arising for CCS-specific survey design is whether the standard VMD system is adequate for delineating a resistive freshwater plume within the relatively conductive brine-saturated environment.…”
Section: Error-metric Comparison: 3d Imaging Of Crosswell Vmd Datamentioning
confidence: 99%
See 2 more Smart Citations
“…Given the sensitivity differences that VMD and VED systems exhibit for resistive targets (Harris and Pethick, 2011;Grayver and Streich, 2014), an important question arising for CCS-specific survey design is whether the standard VMD system is adequate for delineating a resistive freshwater plume within the relatively conductive brine-saturated environment.…”
Section: Error-metric Comparison: 3d Imaging Of Crosswell Vmd Datamentioning
confidence: 99%
“…Complementing sparse borehole-based pressure measurements, due to its larger volumetric coverage, crosswell EM will aid the critical subtask of spatiotemporal plume mapping. The method has shown potential in a variety of applications that involve time-lapse monitoring of subsurface changes due to fluid flow (Alumbaugh and Morrison, 1995a;Wilt and Morea, 2004;Harris and Pethick, 2011;Hu et al, 2016) as well as for general reservoir reconnaissance (Hoversten et al, 2001(Hoversten et al, , 2004Shen et al, 2008;Wilt et al, 2008;Zhang et al, 2017). Here, we focus on the survey design based on simulations of the anticipated freshwater plume evolution.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…At present the only cross-well CSEM systems commercially and readily available are based on vertical magnetic dipole (VMD) transmitting and receiving antennas (SLB, 2008). While the VMD antennas are the only transmitters in use a good case could be made for development of a vertical electrical bipole cross well CSEM source (Harris and Pethick 2011).…”
Section: Introductionmentioning
confidence: 99%