Comparison of a second-generation trabecular bypass (iStent inject) to ab interno trabeculectomy (Trabectome) by exact matching

Abstract: Purpose To achieve a highly balanced comparison of trabecular bypass stenting (IS2, iStent inject) with ab interno trabeculectomy (T, Trabectome) by exact matching. Methods Fifty-three IS2 eyes were matched to 3446 T eyes. Patients were matched using exact matching by baseline intraocular pressure (IOP), the number of glaucoma medications, and glaucoma type, and using nearest neighbor matching by age. Individuals without a close match were excluded. All surgeries were combined with phacoemulsification. Res… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
11
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
6
1

Relationship

3
4

Authors

Journals

citations
Cited by 12 publications
(12 citation statements)
references
References 43 publications
0
11
0
Order By: Relevance
“…Several studies have reported greater postoperative IOP reductions of excisional goniotomy performed using the Kahook Dual Blade (KDB) (New World Medical, Rancho Cucamonga, CA, USA) compared with the iStent [ 19 , 20 , 21 ]. Other studies have shown similar or slightly larger IOP reductions with ab-interno goniotomy performed with the Trabectome (NeoMedix, Tustin, CA, USA) than with the iStent [ 22 , 23 , 24 , 25 ]. The surgical efficacy of µLOT has been comparable to the KDB [ 26 , 27 , 28 ] and ab externo LOT [ 29 ] in multiple studies, although one study reported less chance of achieving surgical success with µLOT than with the Trabectome [ 30 ].…”
Section: Discussionmentioning
confidence: 88%
“…Several studies have reported greater postoperative IOP reductions of excisional goniotomy performed using the Kahook Dual Blade (KDB) (New World Medical, Rancho Cucamonga, CA, USA) compared with the iStent [ 19 , 20 , 21 ]. Other studies have shown similar or slightly larger IOP reductions with ab-interno goniotomy performed with the Trabectome (NeoMedix, Tustin, CA, USA) than with the iStent [ 22 , 23 , 24 , 25 ]. The surgical efficacy of µLOT has been comparable to the KDB [ 26 , 27 , 28 ] and ab externo LOT [ 29 ] in multiple studies, although one study reported less chance of achieving surgical success with µLOT than with the Trabectome [ 30 ].…”
Section: Discussionmentioning
confidence: 88%
“…One study found that in eyes with all stages and types of glaucoma, phaco/Trabectome lowered IOP by 22.7%, which was sustained for 2 years, while the IOP reduction from iStent inject with cataract surgery (phaco/iStent inject) began to wear off at 6 months and became non-significant at 2 years. 15 Despite phaco/Trabectome's IOP-lowering effect, the mean medication reduction between phaco/Trabectome and phaco/ iStent inject was not statistically different. 15 The most frequent complication of Trabectome was bleeding in the form of hyphema (23%-48%), microhyphema (27%-77%), delayed-onset hyphema (5%), and intraoperative blood reflux (59%-100%).…”
Section: Trabectome ®mentioning
confidence: 83%
“…Matching is a nonparametric method designed to control confounding [35]. Propensity score matching would be well suited to compare such dissimilar datasets [36,37], while exact matching is more commonly used to compare similar data [23,38]. However, exact matching allowed us in this study to more carefully examine two of the most important variables in glaucoma care, IOP, and eye drops needed to achieve this IOP.…”
Section: Discussionmentioning
confidence: 99%