2022
DOI: 10.3389/fmed.2021.814519
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of a New Optical Biometer That Combines Scheimpflug Imaging With Partial Coherence Interferometry With That of an Optical Biometer Based on Swept-Source Optical Coherence Tomography and Placido-Disk Topography

Abstract: PurposeTo evaluate measurement precision and to compare the Pentacam AXL (Oculus Optikgeräte, Wetzlar, German), a new optical biometer based on Scheimpflug imaging and partial coherence interferometry (PCI) with that of the OA-2000 biometer (Tomey, Nagoya, Japan), which combines swept-source optical coherence tomography (SS-OCT) and Placido-disk topography.MethodsAxial length (AL), central corneal thickness (CCT), anterior chamber depth (ACD), aqueous depth (AQD), mean keratometry (Km), astigmatism vectors J0,… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(1 citation statement)
references
References 40 publications
(40 reference statements)
0
1
0
Order By: Relevance
“…Similar to our result, a previous study evaluated the Km values obtained by the IOLMaster 700 and OA-2000 and reported a mean difference of 0.00 ± 0.09 D with narrow LoA range [ 11 ]. Moreover, our team had compared the SS-OCT based device with the Scheimpflug based optical biometer (Pentacam AXL, OCULUS) and found comparable outcomes between both devices (95% LoA: − 0.48 D to 0.09 D) [ 21 ]. However, Tañá-Rivero et al [ 22 ] analyzed the interchangeability between the IOLMaster 700 and the Pentacam AXL and demonstrated that the LoA range was wide and may have a significant impact, especially when selecting the Toric IOL power.…”
Section: Discussionmentioning
confidence: 99%
“…Similar to our result, a previous study evaluated the Km values obtained by the IOLMaster 700 and OA-2000 and reported a mean difference of 0.00 ± 0.09 D with narrow LoA range [ 11 ]. Moreover, our team had compared the SS-OCT based device with the Scheimpflug based optical biometer (Pentacam AXL, OCULUS) and found comparable outcomes between both devices (95% LoA: − 0.48 D to 0.09 D) [ 21 ]. However, Tañá-Rivero et al [ 22 ] analyzed the interchangeability between the IOLMaster 700 and the Pentacam AXL and demonstrated that the LoA range was wide and may have a significant impact, especially when selecting the Toric IOL power.…”
Section: Discussionmentioning
confidence: 99%