2017
DOI: 10.1016/j.jhsa.2017.01.003
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of 2-Dimensional and 3-Dimensional Metacarpal Fracture Plating Constructs Under Cyclic Loading

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
20
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(20 citation statements)
references
References 18 publications
0
20
0
Order By: Relevance
“…Furthermore, the maximum fracture force and stiffness values obtained by Barr et al were slightly lower than those obtained in the current study; we inferred that this might be caused by the different brand of the bone plates and the different number of fixation screws used. Additionally, Tannenbaum et al [ 27 ] similarly used locking plates for fixating metacarpal shaft fractures. The fracture force and stiffness values they obtained were 190 + 17 N and 11.2 + 1.0 N/mm, respectively.…”
Section: Discussionmentioning
confidence: 99%
“…Furthermore, the maximum fracture force and stiffness values obtained by Barr et al were slightly lower than those obtained in the current study; we inferred that this might be caused by the different brand of the bone plates and the different number of fixation screws used. Additionally, Tannenbaum et al [ 27 ] similarly used locking plates for fixating metacarpal shaft fractures. The fracture force and stiffness values they obtained were 190 + 17 N and 11.2 + 1.0 N/mm, respectively.…”
Section: Discussionmentioning
confidence: 99%
“…Some of these rotation abnormalities may be due to the use of a single KW, with no locking device to fix the fracture. [ 18 ]…”
Section: Discussionmentioning
confidence: 99%
“…Tannenbaum and colleagues attempted to address this issue by examining possible differences in construct stability regarding smaller 3-dimensional and larger 2-dimensional plates for fixation of metacarpal fractures. They propose that lowerprofile 3-dimensional plates provide greater stability and reduce complications such as soft tissue stripping, plate prominence, and tendonitis (Tannenbaum et al, 2017). One study has evaluated total length, proximal metaphyseal width, distal metaphyseal width, isthmus width and medullary canal width in 50 radiographic cadaver hands, in efforts to provide preliminary data for locked metacarpal nail design (Boonyasirikool and Niempoog, 2014).…”
Section: Introductionmentioning
confidence: 99%