2020
DOI: 10.1097/md.0000000000018582
|View full text |Cite
|
Sign up to set email alerts
|

Comparison between using INTEGRA and manual method in determining axis for intraocular lens implantation

Abstract: The aim of this study was to explore the efficacy, repeatability, and efficiency of a new intraoperative contactless device (INTEGRA Optomed, Chorzów, Poland) for determining the axis for toric intraocular lens implantation and then to compare this with that determined using a manual method. This study was conducted at the Ophthalmological Center for Children and Adults Optomed, Chorzów, Poland. This nonrandomized, retrospective, observational study included 20 eyes of 12 patients (5 ma… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
15
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(16 citation statements)
references
References 13 publications
1
15
0
Order By: Relevance
“…As shown in various studies, the post-operative rotation of toric IOLs is observed more often in early post-operative period, and even as early as 1 h after the surgery. [12,13,15] However, no significant differences in rotational stability were noted after 1-week. This is why we performed rotational stability evaluation at 1-week post-op, as toric IOL position usually settles by this time and rotations, if any, can be diagnosed and managed easily.…”
Section: Discussionmentioning
confidence: 87%
See 2 more Smart Citations
“…As shown in various studies, the post-operative rotation of toric IOLs is observed more often in early post-operative period, and even as early as 1 h after the surgery. [12,13,15] However, no significant differences in rotational stability were noted after 1-week. This is why we performed rotational stability evaluation at 1-week post-op, as toric IOL position usually settles by this time and rotations, if any, can be diagnosed and managed easily.…”
Section: Discussionmentioning
confidence: 87%
“…[20][21][22][23] Several IOL alignment methods, including manual marking, iris-fingerprinting technique, intraoperative wavefront aberrometry, and automated intraoperative registration systems have been thus evaluated to improve the accuracy of results with toric IOLs. [11][12][13][14][15] Varsits et al, in a recent study evaluated the CALLISTO eye software, an intraoperative toric intraocular lens alignment system with an image-guided system. [15] They concluded that it was an accurate and fast procedure resulting in precise alignment, simplifying the positioning of toric IOLs.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…[ 10 11 12 13 ] Therefore, there are several IOL alignment methods, including manual marking, iris-finger printing technique, intra-operative wavefront aberrometry, and automated intra-operative registration systems, such as the investigated system, or the Verion system (Alcon Laboratories, Inc.). [ 14 15 16 ]…”
Section: Discussionmentioning
confidence: 99%
“…Automatic systems for determining the axis of the implant are becoming increasingly common. Such methods involve overlaying an image on the eye in real time to guide the incision site and capsulorhexis and they use the Technischer Ausschuss für BrillenOptik (TABO) scale to facilitate axial positioning of the intraocular lens in the eyeball [ 3 , 4 ] ( Figure 1 ).…”
Section: Introductionmentioning
confidence: 99%