2017
DOI: 10.1049/iet-gtd.2016.0849
|View full text |Cite
|
Sign up to set email alerts
|

Comparison between traditional single‐phase auto reclosing and adaptive technique based on harmonic content measurement

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
20
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 35 publications
(20 citation statements)
references
References 18 publications
(9 reference statements)
0
20
0
Order By: Relevance
“…In terms of adaptive protection, a very important issue in a smart grids environment, reference Dias and Tavares (2017a), shows an approach which a digital harmonic filter is implemented to improve the performance of a distance relay. Smart grids demand smarter protection systems, and the comparative results shown in Dias and Tavares (2017b) reinforce the efficiency of the use of adaptive techniques opposite to the use of traditional protection methods. The advancement of technology in energy distribution allows new approaches to be used for protection systems as is shown in Faria et al (2018).Additionally, reference Renzo and Fabian (2018) proposes a faulted phase selection algorithm for distance protection applied to half-wavelength power transmission lines, with the purpose of considering these lines characteristics in a more proper way than fault selection algorithms used in conventional relays.…”
Section: Power System Protectionmentioning
confidence: 83%
“…In terms of adaptive protection, a very important issue in a smart grids environment, reference Dias and Tavares (2017a), shows an approach which a digital harmonic filter is implemented to improve the performance of a distance relay. Smart grids demand smarter protection systems, and the comparative results shown in Dias and Tavares (2017b) reinforce the efficiency of the use of adaptive techniques opposite to the use of traditional protection methods. The advancement of technology in energy distribution allows new approaches to be used for protection systems as is shown in Faria et al (2018).Additionally, reference Renzo and Fabian (2018) proposes a faulted phase selection algorithm for distance protection applied to half-wavelength power transmission lines, with the purpose of considering these lines characteristics in a more proper way than fault selection algorithms used in conventional relays.…”
Section: Power System Protectionmentioning
confidence: 83%
“…Furthermore, according to [34,35], a secondary arc model was established as follows, and it was added in the simulation experiments…”
Section: Simulation Resultsmentioning
confidence: 99%
“…The secondary arc extinction is the beginning of the recovery voltage stage. Dias and Tavares [1] have proposed many methods to distinguish the arc extinction. Especially the secondary arc has larger odd harmonics and uncertain characteristics.…”
Section: Fault Identification and Adaptive Autoreclosing Schemementioning
confidence: 99%
“…Majority of power system failures are transmission line failures. Higher voltage level has more probability of single line to ground (SLG) fault [1]. Most of SLG faults are temporary mainly caused by atmospheric discharges.…”
Section: Introductionmentioning
confidence: 99%