2008
DOI: 10.1093/alcalc/agm175
|View full text |Cite
|
Sign up to set email alerts
|

Comparison between the urinary alcohol markers EtG, EtS, and GTOL/5-HIAA in a controlled drinking experiment

Abstract: This study is the first controlled experiment comparing the time-courses for ethanol, EtG, EtS, and GTOL/5-HIAA in urine. In cases where surveillance of alcohol relapse is needed, measurements of urinary EtG and EtS are sensitive and specific alternatives to ethanol testing. The GTOL/5-HIAA ratio is equally sensitive but with a much shorter window of detection.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

5
65
1

Year Published

2010
2010
2024
2024

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 105 publications
(71 citation statements)
references
References 28 publications
5
65
1
Order By: Relevance
“…There was no explanation for this, but error in the analysis could not be excluded. EtG are however quite short in blood, ~10 h, according to our results (paper I and IV) and others (134) and the problem would be more pronounced if EtG and EtS were only analyzed in urine, in which this difference might be up to several days (45,61). This shows how the analysis in blood and urine complement each other; the risk of false negatives caused by instability is highest in blood and the risk of false positives from previous ethanol ingestions is highest in urine.…”
Section: Use Of Etg and Ets As A Marker Of Ante Mortem Alcohol Ingestsupporting
confidence: 80%
See 2 more Smart Citations
“…There was no explanation for this, but error in the analysis could not be excluded. EtG are however quite short in blood, ~10 h, according to our results (paper I and IV) and others (134) and the problem would be more pronounced if EtG and EtS were only analyzed in urine, in which this difference might be up to several days (45,61). This shows how the analysis in blood and urine complement each other; the risk of false negatives caused by instability is highest in blood and the risk of false positives from previous ethanol ingestions is highest in urine.…”
Section: Use Of Etg and Ets As A Marker Of Ante Mortem Alcohol Ingestsupporting
confidence: 80%
“…Levels of EtS in blood have been reported in one other low dose experiment (134) as well as in our study of heavy drinkers (paper V). Both our studies and other studies of EtG and EtS in blood and urine indicated that levels of EtG were higher than the corresponding levels of EtS (61,155), also when corrected for different molecular weight, with molar EtG/EtS ratios reported as 1.7. Only one study in urine showed higher concentrations of EtS than EtG (161), and similar molar concentrations of EtG and EtS were seen in serum in the kinetic study by the same group (134), although the AUC was higher for EtG.…”
Section: Blood Kinetics Of Etg and Ets In Living Subjectssupporting
confidence: 74%
See 1 more Smart Citation
“…The 5‐HTOL/5‐HIAA ratio increases appreciably in urine after alcohol intake and is a promising marker for recent alcohol intake with a short window of detection. Until now, it has not found its way into clinical routine because of costly detection assays 47, 48…”
Section: Biomarkersmentioning
confidence: 99%
“…A supplementary method to distinguish antemortem ethanol consumption from postmortem ethanol formation is the analysis of the ethanol metabolites ethyl glucuronide (EtG) and ethyl sulfate (EtS) (4)(5)(6)(7). These metabolites are produced by enzymatic conjugation of ethanol in living individuals (8,9). However, as EtG and EtS represent only a small fraction (i.e.…”
Section: Introductionmentioning
confidence: 99%