Comparison Between Ocular Biometric Parameters and Intraocular Pressure With and Without Contact Lenses

Veronica Noya-Padin,
Noelia Nores-Palmas,
Maria Jesus Giraldez
et al.

Abstract: Objectives: To compare the values of central corneal thickness, anterior chamber depth (ACD), lens thickness (LT), vitreous length (VL), axial length (AL), and corneal-compensated intraocular pressure performed with and without contact lenses (CL). Methods: Forty volunteer participants (16 men and 24 women, 24.2±2.9 years) were recruited. In a single visit, participants underwent autorefraction, keratometry, biometry, topography, pachymetry, and tonomet… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
2
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
3

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 39 publications
0
2
0
Order By: Relevance
“…Objective refraction was performed using the Shin-Nippon NVISION-K 5001 (Rexxam Co., Kagawa, Japan) [28,29]. This device is an open-field autorefractometer, so the fixation target is external and located at a distance.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Objective refraction was performed using the Shin-Nippon NVISION-K 5001 (Rexxam Co., Kagawa, Japan) [28,29]. This device is an open-field autorefractometer, so the fixation target is external and located at a distance.…”
Section: Methodsmentioning
confidence: 99%
“…The refractive power is measured in 0.12 D steps, and the cylindrical axis is measured in 1º increments. For the measurements, the vertex distance was always automatically set at 12 mm [28].…”
Section: Methodsmentioning
confidence: 99%
“…A Lenstar LS900 (Haag-Streit, Köniz, Switzerland), based on optical low-coherence reflectometry, was used to obtain the CCT and ACD values [16,[39][40][41]. In all measurements, the instrument was set automatically; once the operator started the measurement, the device automatically averaged three consecutive measurements.…”
Section: Lenstar Ls900 Ocular Biometermentioning
confidence: 99%
“…Based on the Ultrasound A principle, a US-800 biometry NIDEK EchoScan Ultrasound Model (Nidek Co., Tokyo, Japan) was used to obtain the ACD [8,9,40,41]; this device does not provide the CCT value as an independent parameter from the ACD. The device was used in contact mode, taking care to prevent cornea indentation.…”
Section: Echoscan Us-800 Ocular Biometermentioning
confidence: 99%