2015
DOI: 10.1016/j.nima.2014.11.017
|View full text |Cite
|
Sign up to set email alerts
|

Comparison between large area photo-multiplier tubes at cryogenic temperature for neutrino and rare event physics experiments

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
13
0

Year Published

2016
2016
2019
2019

Publication Types

Select...
5
2

Relationship

3
4

Authors

Journals

citations
Cited by 12 publications
(14 citation statements)
references
References 8 publications
1
13
0
Order By: Relevance
“…Starting from the centre, it can be noted a slight decrease of the QE, followed by a continuous increase up to the windows border. These variations, within ±5% around the QE mean value, reflect the sensitivity variation of the bialkali photo cathode to visible light without TPB coating, as shown by the dashed curve in the same plot [9][10].…”
Section: Quantum Efficiency Measurements On Pmtsmentioning
confidence: 75%
“…Starting from the centre, it can be noted a slight decrease of the QE, followed by a continuous increase up to the windows border. These variations, within ±5% around the QE mean value, reflect the sensitivity variation of the bialkali photo cathode to visible light without TPB coating, as shown by the dashed curve in the same plot [9][10].…”
Section: Quantum Efficiency Measurements On Pmtsmentioning
confidence: 75%
“…Single photo electron response (SER) was studied, as a function of the position of the fiber along two perpendicular diameters, to estimate photo-cathode uniformity. Hamamatsu PMTs showed a good uniformity, within 10%, up to 10 cm from the tube axis, where a gain reduction occurs, probably due to the electric field non uniformity in the peripheral region of the tube (see also [3,4]). This behavior does not occur with ETL 9357 KFLB, where the uniformity remains within 10% up to the border of the PMT windows (see Fig.…”
Section: Characterization At Room Temperaturementioning
confidence: 99%
“…PMTs were illuminated with a 405 nm laser diode 1 , using a pulse generator 2 and an optical fiber 3 . A proper support was used to maintain the fiber at a fixed orientation, normal to the PMT window, while allowing to move it in various positions on the window itself.…”
Section: Characterization At Room Temperaturementioning
confidence: 99%
See 1 more Smart Citation
“…At the time of the Workshop tests wre under way to select the most suitable PMT model [17]. Three large area (8") PMTs: Hamamatsu R5912 Mod and R5912-02 Mod and ETL 9357 KFLB have been studied, both at room and cryogenic temperature.…”
Section: Upgraded Light Collection Systemmentioning
confidence: 99%