Comparison between invasive blood pressure and a non-invasive blood pressure monitor in anesthetized sheep

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
13
1
3

Year Published

2017
2017
2021
2021

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 13 publications
(19 citation statements)
references
References 17 publications
2
13
1
3
Order By: Relevance
“…Invasive method proved to yield significantly more repeatable BP measurements (as indicated by significantly lower CV%) than oscillometry and Doppler. Generally, the range of CV% observed was wide although quite similar to previously obtained [ 19 ] and DBP was recorded with greater variability than the other two BPs ( S1 File ). On the other hand, both the CV% and the number of outliers identified in this study were lower than in the study carried out before in conscious goats [ 15 ], which implies that alleviation of goat anxiety by anesthesia improves the repeatability of BP measurements.…”
Section: Discussionsupporting
confidence: 88%
See 2 more Smart Citations
“…Invasive method proved to yield significantly more repeatable BP measurements (as indicated by significantly lower CV%) than oscillometry and Doppler. Generally, the range of CV% observed was wide although quite similar to previously obtained [ 19 ] and DBP was recorded with greater variability than the other two BPs ( S1 File ). On the other hand, both the CV% and the number of outliers identified in this study were lower than in the study carried out before in conscious goats [ 15 ], which implies that alleviation of goat anxiety by anesthesia improves the repeatability of BP measurements.…”
Section: Discussionsupporting
confidence: 88%
“…Ninety five per cent of oscillometric BP measurements are expected to differ from invasive BP measurements by at most 20–25 mmHg, which is less than allowed by ACVIM guidelines (1.96 × SD of 15 mmHg which is ±30 mmHg from the bias between invasive and non-invasive method; [ 4 ]). Agreement in our study was better than showed in adult sheep [ 18 , 19 ] or in the mixed group of adult goats and sheep [ 20 ] between invasive BP on the auricular arteria and oscillometry on the left thoracic limb. Nevertheless, the identical tendencies were observed: in the three aforementioned studies, like in ours, SBP was not significantly biased (the mean difference of 0), while both DBP and MBP were significantly underestimated by oscillometry.…”
Section: Discussioncontrasting
confidence: 58%
See 1 more Smart Citation
“…On the other hand, Heard et al (38) disagreed with these results regarding relationship between non-invasive & invasive as they analyzed ABP data obtained by noninvasive method and found variation in results when compared with invasive method. Furthermore, Acierno et al (39) Shih et al (40) and Almeida (41) found a difference between the two methods. Based on that critical care nurses are responsible for monitoring patients' hemodynamical status and reporting any deviation from normal, they have to know the effect of certain drugs on vital signs to obtain hemodynamic stability.…”
Section: Discussionmentioning
confidence: 98%
“…In sedated sheep, the difference between invasive and a non invasive blood pressure measurements are taken. The objective of this examination was to decide the accuracy of the petMAP in anesthetized sheep confronting a medical procedure [2].Machine learning techniques and characteristic features of the photo plethysmography signals are utilized for the measurement of hemoglobin non-invasively [3].A noninvasive antenatal finding of hb Bart's disease by cardiothoracic ratio over the first period was given [4].The effects of a sympathetic block on Plethysmographic analysis of Hb concentration, Perfusion and Pleth variability Index with the Radical-7 apparatus was studied [5].The hb concentration in arterial blood was measured non-invasively. For this purpose a magnet was used which is set essentially over the radial artery of an individual whose hb concentration is to be discovered [6].Observable Red Laser light of wavelength 650 nm was used by the simple and beneficial noninvasive device for Blood Glucose Monitoring (RL-BGM) [7].The impacts of Skin thickness and Fingerprints was pretended to show the issues with Noninvasive RF Blood Glucose Sensing from Fingertips [8].…”
Section: Related Workmentioning
confidence: 99%