2014
DOI: 10.1016/j.ajodo.2013.09.008
|View full text |Cite
|
Sign up to set email alerts
|

Comparison between electrochemical ELISA and spectrophotometric ELISA for the detection of dentine sialophosphoprotein for root resorption

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
21
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 17 publications
(21 citation statements)
references
References 15 publications
0
21
0
Order By: Relevance
“…The detection limit reached using our device is comparable with values reported in previously published studies describing electrochemical ELISA carried out with different devices and antigen/antibody pairs. For example, Nemiroski et al 2 reported a LOD of 20 ng mL −1 for Pf HRP2, Bhimji et al 8 reported a LOD of 1 ng mL −1 for HIV-1 antibodies, Sun et al 55 reported a LOD of 0.5 ng mL −1 for cucumber mosaic virus, Liu et al 4 reported a LOD of 0.02 ng mL −1 for α-fetoprotein, and Sha et al 3 reported a LOD of 0.5 pg mL −1 for the detection of dentine sialophosphoprotein. Electrochemical Sandwich ELISA for Detection of Pf HRP2.…”
Section: ■ Results and Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The detection limit reached using our device is comparable with values reported in previously published studies describing electrochemical ELISA carried out with different devices and antigen/antibody pairs. For example, Nemiroski et al 2 reported a LOD of 20 ng mL −1 for Pf HRP2, Bhimji et al 8 reported a LOD of 1 ng mL −1 for HIV-1 antibodies, Sun et al 55 reported a LOD of 0.5 ng mL −1 for cucumber mosaic virus, Liu et al 4 reported a LOD of 0.02 ng mL −1 for α-fetoprotein, and Sha et al 3 reported a LOD of 0.5 pg mL −1 for the detection of dentine sialophosphoprotein. Electrochemical Sandwich ELISA for Detection of Pf HRP2.…”
Section: ■ Results and Discussionmentioning
confidence: 99%
“…We connected the paper device to the potentiostat using a reusable magnetic PDMS holder ( Figure S4). The PDMS holder consisted of two parts (a top part, 3 × 1.1 × 0.5 cm 3 , and a Figure 1. Fabrication of paper-based electrochemical devices.…”
Section: ■ Experimental Sectionmentioning
confidence: 99%
“…Moreover, it is possible that our samples were either too diluted for subsequent analysis or the traditional ELISA method was not sufficiently sensitive to detect DSP in GCF. Recently, Sha et al 21 recommended a novel method that combines ELISA with electrochemical analysis of GCF samples for the detection of dentin proteins. The authors state that the high sensitivity of this method extends the detection limit of the assay and could be a new way to measure dentin proteins in minute samples such as GCF.…”
Section: Discussionmentioning
confidence: 99%
“…In recent years, ELISA combined with electrochemical detection has extended the limit of detection by a factor of 10 with small biological samples [33] yet there has been no appreciable decrease in cost. In this work, the classical sandwich ELISA was modified to detect antigen by using an electrochemical technique (Fig.…”
Section: Electrochemical Sandwich Elisamentioning
confidence: 99%