Comparison between EGSnrc and MCNPX for X-ray target in 6 MV photon beam

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
5
0
1

Year Published

2021
2021
2023
2023

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 8 publications
0
5
0
1
Order By: Relevance
“…Because of the low kV energy (50 kV) used in this study, the relative depth-dose values shown in Figure 3 drop rapidly for both MCNP4c and EGSnrc/ Epp MC codes. The statistical uncertainties [11]. In another study, EGSnrc/ Epp MC codes were at least two times faster than DOSXYZnrc (slightly modified from the official version for saving phase space information of the photons leaving the geometry) [12].…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Because of the low kV energy (50 kV) used in this study, the relative depth-dose values shown in Figure 3 drop rapidly for both MCNP4c and EGSnrc/ Epp MC codes. The statistical uncertainties [11]. In another study, EGSnrc/ Epp MC codes were at least two times faster than DOSXYZnrc (slightly modified from the official version for saving phase space information of the photons leaving the geometry) [12].…”
Section: Discussionmentioning
confidence: 99%
“…Yani et al, have also compared EGSnrc using a phase space scoring plane with MCNPX for X-ray target in 6 MV photon beam using statistical uncertainty and simulation time. According to his study, EGSnrc MC codes were faster and more efficient than MCNPX MC codes in simulation time and statistical uncertainty [ 11 ]. In another study, EGSnrc/Epp MC codes were at least two times faster than DOSXYZnrc (slightly modified from the official version for saving phase space information of the photons leaving the geometry) [ 12 ].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Dosimetri pada CBCT menjadi cukup penting karena penggunaan IGRT dan CT scanner multislice yang cukup sering. CBCT memiliki beberapa jenis modalitas salah satunya adalah varian On Board Imager (OBI) v1.4 yang dirilis pada tahun 2008 (Yani, 2019).…”
Section: Pendahuluanunclassified
“…Thus, computational simulations can be performed as an alternative to experimental methods to obtain valuable information with the prediction of computational results [31][32][33][34][35]. Several Monte Carlobased codes are used in physics research [36][37][38][39][40][41]. The MCNPX code was developed to study particle physics and nuclear reactions, so they simulate an extensive set of particles in a broad energy spectrum [42][43][44][45] and many medical physics applications [46][47][48][49][50].…”
Section: Introductionmentioning
confidence: 99%