2011
DOI: 10.4103/1817-1737.74274
|View full text |Cite
|
Sign up to set email alerts
|

Comparison and agreement between venous and arterial gas analysis in cardiopulmonary patients in Kashmir valley of the Indian subcontinent

Abstract: BACKGROUND:Arterial blood gas (ABG) analysis is routinely performed for sick patients but is fraught with complications, is painful, and is technically demanding.OBJECTIVE:To ascertain agreement between the arterial and peripheral venous measurement of pH, pCO2, pO2, and bicarbonate levels in sick patients with cardiopulmonary disorders in the valley of Kashmir in the Indian subcontinent, so as to use venous gas analysis instead of arterial for assessment of patients.SETTING:Sher-i-Kashmir Institute of Medical… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
17
1
1

Year Published

2011
2011
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 28 publications
(20 citation statements)
references
References 23 publications
1
17
1
1
Order By: Relevance
“…Of these, 7695 were excluded as they failed to meet the inclusion criteria (most were not relevant to the study question as there was no direct comparison of VBG and ABG analyses, others were performed on paediatric populations or the VBG sample was central or mixed venous). The remaining 32 full‐text articles were examined for eligibility, and a further 14 studies were excluded (nine studies had incomplete data required for the meta‐analysis, four studies were not PVBG samples, and one study was performed on cardiopulmonary bypass) . The remaining 18 separate studies were included in the qualitative synthesis and contributed data to the meta‐analysis (Fig.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Of these, 7695 were excluded as they failed to meet the inclusion criteria (most were not relevant to the study question as there was no direct comparison of VBG and ABG analyses, others were performed on paediatric populations or the VBG sample was central or mixed venous). The remaining 32 full‐text articles were examined for eligibility, and a further 14 studies were excluded (nine studies had incomplete data required for the meta‐analysis, four studies were not PVBG samples, and one study was performed on cardiopulmonary bypass) . The remaining 18 separate studies were included in the qualitative synthesis and contributed data to the meta‐analysis (Fig.…”
Section: Resultsmentioning
confidence: 99%
“…incomplete data required for the meta-analysis, four studies were not PVBG samples, and one study was performed on cardiopulmonary bypass). 6, 16 The remaining 18 separate studies were included in the qualitative synthesis and contributed data to the meta-analysis ( Fig. 1); 16 assessed PCO2, 15 assessed pH, and 11 assessed PO2.…”
Section: Characteristics Of the Studiesmentioning
confidence: 99%
“…Blood glucose, lactate, and parameters defining acid-base status (pH, pCO 2 , HCO 3 ) were documented for all venous blood samples. Current approaches envisage a cautionary view in evaluating the peripheral venous lactate instead of arterial lactate, especially for significant high value levels [25][26][27][28][29][30][31]. However, recent reviews on lactate measurement (arterial versus venous blood sampling) revealed very strong correlations between arterial and venous lactate concentrations [32].…”
Section: Blood Glucose Lactate and Acid-base Status Evaluationmentioning
confidence: 99%
“…The use of venous sampling in the management of diabetic ketoacidosis has been standard practice in paediatric patients for many years [2]. Although venous blood gas analysis has been recommended in adults for post‐diagnosis monitoring of acid‐base status [1,3], results from previous studies do not consistently suggest that the two sites can be used interchangeably [4–10]. Lack of duplication of each assay in these studies prevents assessment of the precision of the instruments used for the population studied, making it unclear whether perceived differences between sample sites in fact reflect instrument imprecision [11].…”
Section: Introductionmentioning
confidence: 99%