2020
DOI: 10.1016/j.ejmp.2019.12.023
|View full text |Cite
|
Sign up to set email alerts
|

Comparison among four immobilization devices for whole breast irradiation with Helical Tomotherapy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 20 publications
0
5
1
Order By: Relevance
“…24 In the present study, we did not assess patient comfort; however, patient positioning as described is consistent with the literature recommendation regarding setup reproducibility. 20,21 Thermoplastic mask and skin reactions Contrary to other data showing that the use of a mask increased the surface dose and subsequently increased skin reactions, 25 in this study, patients with a mask experienced nearly 2 times less grade 2 to 4 skin reactions. However, stratified analysis demonstrated that this is related to the difference in fractionation regimen and eventually to the total dose prescription.…”
Section: Impact Of Bra Use and Other Immobilization Techniquescontrasting
confidence: 75%
See 1 more Smart Citation
“…24 In the present study, we did not assess patient comfort; however, patient positioning as described is consistent with the literature recommendation regarding setup reproducibility. 20,21 Thermoplastic mask and skin reactions Contrary to other data showing that the use of a mask increased the surface dose and subsequently increased skin reactions, 25 in this study, patients with a mask experienced nearly 2 times less grade 2 to 4 skin reactions. However, stratified analysis demonstrated that this is related to the difference in fractionation regimen and eventually to the total dose prescription.…”
Section: Impact Of Bra Use and Other Immobilization Techniquescontrasting
confidence: 75%
“…The results showed that mask performance ranked second after the BlueBag system with Arm-Shuttle (Elekta, Sweden), with no statistically significant difference between the 2 techniques in a pairwise comparison. 21…”
Section: Accuracy Of Thermoplastic Mask In the Literaturementioning
confidence: 99%
“…The importance of breast radiotherapy is rising, with the increasing component rate of early-stage breast cancer 17 . The setup errors have always being a vexing problem during radiotherapy [18][19][20][21] . It plays an important role in the delineation and definition of PTV [21][22][23][24] or ITV 25 , and therefore affects radiation effect [25][26][27][28] and toxicity 29,30 of the patients.…”
Section: Discussionmentioning
confidence: 99%
“…But because of the expensive cost and technical challenges, many hospitals, including our hospital, cannot perform this BIS. The major BIS in the irradiation department of this hospital is still the breast bracket, Vacuum-lock bag or thermoplastic mask 19 . Previous studies on the breast cancer radiotherapy fixation devices mainly focused on vacuum bag [9][10][11][12][13] , breast board [7][8][9] , and alpha cradle 14,15 .…”
Section: Discussionmentioning
confidence: 99%
“…[1][2][3] Therefore, studies have shown that an effective immobilization device can reduce setup errors and lead to better treatment outcomes. [4][5][6][7][8] Six-dimensional (6D) setup errors, including 3 translations (vertical, longitudinal, and lateral) and 3 rotations (roll, yaw, and pitch), can be detected by cone beam computed tomography (CBCT) and corrected by 6D couches. As we all know, most modern linear accelerators (LINACs) have 6D couches available as an option, and all modern proton systems utilize 6D couch corrections.…”
Section: Introductionmentioning