Comparing Water Absorption of Food and Drug Administration–Approved Hyaluronic Acid Fillers

Abstract: BACKGROUNDTo compare the water absorption of 12 FDA-approved hyaluronic acid (HA) facial fillers in vitro in conditions relevant to in vivo injection.OBJECTIVEThe goal of this study was to provide long-term insight into an improved, tailored facial rejuvenation approach and to understand sequelae that could affect preoperative surgical planning.METHODSIn 2 experiments, 12 FDA-approved HA fillers were loaded into test tubes with nonpreserved normal saline and then placed in a 94.5°F–96°F environment for 1 month… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(1 citation statement)
references
References 18 publications
0
1
0
Order By: Relevance
“…In a later study, investigators rotated the centrifuge at 1200rpm for twelve minutes (total of 14,400 revolutions) and raised concerns that longer durations could potentially compress the saline out of the hydrated HA. 10 To ensure our results could be compared to these earlier works and account for the aforementioned concerns regarding the potential compression of the sample, we arbitrarily reduced the centrifuging time to five minutes since our centrifuge rotated at the same speed as that used in the first paper (total of 17,500 revolutions). After the centrifugation was completed, 10 μL of blue dye (DipQuick counter stain # 3) was gently pipetted onto the top surface of the sample.…”
Section: Methodsmentioning
confidence: 99%
“…In a later study, investigators rotated the centrifuge at 1200rpm for twelve minutes (total of 14,400 revolutions) and raised concerns that longer durations could potentially compress the saline out of the hydrated HA. 10 To ensure our results could be compared to these earlier works and account for the aforementioned concerns regarding the potential compression of the sample, we arbitrarily reduced the centrifuging time to five minutes since our centrifuge rotated at the same speed as that used in the first paper (total of 17,500 revolutions). After the centrifugation was completed, 10 μL of blue dye (DipQuick counter stain # 3) was gently pipetted onto the top surface of the sample.…”
Section: Methodsmentioning
confidence: 99%