2013
DOI: 10.1016/j.crad.2013.06.004
|View full text |Cite
|
Sign up to set email alerts
|

Comparing T1-weighted and T2-weighted three-point Dixon technique with conventional T1-weighted fat-saturation and short-tau inversion recovery (STIR) techniques for the study of the lumbar spine in a short-bore MRI machine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
38
0
1

Year Published

2015
2015
2019
2019

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 46 publications
(40 citation statements)
references
References 28 publications
1
38
0
1
Order By: Relevance
“…If the fat suppression quality of T2 Dixon is superior to that of conventional techniques, T2 Dixon is expected to demonstrate its clinical usefulness as it not only reduces the scan time but also obtains a better quality fat suppression image. There have been several reports comparing T2 Dixon and conventional fat suppression techniques in the evaluation of the lumbar spine (3,8,12). However, to our best knowledge, there has been no comparative study of T2 Dixon and SPAIR which are more advanced fat suppression techniques.…”
mentioning
confidence: 95%
See 1 more Smart Citation
“…If the fat suppression quality of T2 Dixon is superior to that of conventional techniques, T2 Dixon is expected to demonstrate its clinical usefulness as it not only reduces the scan time but also obtains a better quality fat suppression image. There have been several reports comparing T2 Dixon and conventional fat suppression techniques in the evaluation of the lumbar spine (3,8,12). However, to our best knowledge, there has been no comparative study of T2 Dixon and SPAIR which are more advanced fat suppression techniques.…”
mentioning
confidence: 95%
“…Several fat suppression techniques have been developed and widely used: chemical shift-selective saturation (CHESS), short-tau inversion recovery (STIR) and spectral attenuated inversion recovery (SPAIR) (6)(7)(8). The CHESS and STIR have advantages and disadvantages.…”
mentioning
confidence: 99%
“…The mDixon sequences included one in-phase and two out-of-phase loops (water and fat protons), which resulted in three separate echoes. 3 Fat and water phase shift for each echo was 0, p and 2p. For fat-water separation, a phase-unwrapping algorithm was adopted.…”
Section: Mr Parametersmentioning
confidence: 99%
“…2 The three-point Dixon (mDixon) technique using a three-phase difference (0, p and 2p) between fat and water signals allows a flexible echo time and sequence design and compensates for B 0 field heterogeneity. 3 The mDixon therefore produces homogeneous fat and water separation that is less sensitive to B 0 field heterogeneity. 4,5 The mDixon technique provides rapid T 2 weighted imaging (T2WI) with and without FS; addition and subtraction of the separate images yields a fatonly and a water-only image.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation