2017
DOI: 10.1016/j.applthermaleng.2016.12.026
|View full text |Cite
|
Sign up to set email alerts
|

Comparative study on the performance of a new solar air collector with different surface shapes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
25
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 58 publications
(26 citation statements)
references
References 18 publications
1
25
0
Order By: Relevance
“…The results obtained in this study are very similar to a number of studies. [3][4][5][6][7][8][9]11 In accordance with these references, a tight air channel which the width is between 7.5 cm and 10 cm results in a significant improvement in the performance of the collector. In addition, the collector efficiency improves with increasing of mass flow due to improved heat transfer to the air flow.…”
Section: The Efficiency Variation Of the Solar Collectors Systemssupporting
confidence: 65%
See 1 more Smart Citation
“…The results obtained in this study are very similar to a number of studies. [3][4][5][6][7][8][9]11 In accordance with these references, a tight air channel which the width is between 7.5 cm and 10 cm results in a significant improvement in the performance of the collector. In addition, the collector efficiency improves with increasing of mass flow due to improved heat transfer to the air flow.…”
Section: The Efficiency Variation Of the Solar Collectors Systemssupporting
confidence: 65%
“…Li et al presented a comparative study on the performance of a new solar air collector with different surface shapes: sinusoidal corrugated plate, protrusion plate, sinusoidal corrugated and protrusion plate and a base flat-plate. 3 The results show that the changing shape of the absorber plate is better than the flat plate. Gianpiero et al reviewed the experimental results in flat solar thermal collectors over the past decade.…”
Section: Introductionmentioning
confidence: 94%
“…When comparative tests are to be conducted, all the solar heating collectors should be supported on the same roof in order to ensure the same extent of intensity of solar radiation falling on them to minimize the uncertainty or error. 134 Finally, by identifying the uncertain factors at the design stage can enhance further research on optimization of uncertainty for solar air heaters and can be accurately solved. Therefore, during planning and design of experiments, uncertainty analysis is capable of producing an intended result that is desired to establish the validity and accuracy of the experiments.…”
Section: F I G U R E 1mentioning
confidence: 99%
“…In the Solar Drying method the food and perishable items are directly placed on the ground floors, which can reach temperatures higher than the temperatures in open drying, and left there for a number of days to dry [9]. In solar air heaters, heat transfer from sun to absorber and absorber to fluid occurs.…”
Section: Introductionmentioning
confidence: 99%