2015 IEEE 15th International Conference on Environment and Electrical Engineering (EEEIC) 2015
DOI: 10.1109/eeeic.2015.7165426
|View full text |Cite
|
Sign up to set email alerts
|

Comparative study on sudden short-circuit currents of a synchronous generator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
4
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 6 publications
0
4
0
Order By: Relevance
“…In case of dependence on the short-circuit current of generators with salient poles, different values of direct and quadrature parameters of the generator should be taken into account [22,23,25,26]:…”
Section: The Characteristic Of Low-power Silent Poles Synchronous Generatorsmentioning
confidence: 99%
See 1 more Smart Citation
“…In case of dependence on the short-circuit current of generators with salient poles, different values of direct and quadrature parameters of the generator should be taken into account [22,23,25,26]:…”
Section: The Characteristic Of Low-power Silent Poles Synchronous Generatorsmentioning
confidence: 99%
“…where: One important problem associated with the operation of low-power synchronous generators is the relatively small values of the sub-transient and transient electromagnetic time constants of these generators, generally defined as [22,23,25,26]:…”
Section: The Characteristic Of Low-power Silent Poles Synchronous Generatorsmentioning
confidence: 99%
“…The literature has widely described the phenomena connected with the generator short-circuits [8][9][10][11], but the authors have rarely examined these phenomena in the context of low-power hybrid systems, for example, diesel generators (DGs), where the characteristic low values of the time constants cause fast reaching of the steady-state short-circuit current (which is low as well). The analysis of the obtained results allowed the verification of individual applications of generators in electrical installations in the context of the selection or checking of the installed safety equipment.…”
Section: Introductionmentioning
confidence: 99%
“…In [12], a hybrid model for detecting and diagnosing the turn-to-turn short-circuit fault of wound-rotor synchronous generator is proposed. In [13], the three-phase, two-phase and single-phase transient shortcircuits of the three-phase salient poles synchronous generator are calculated and analyzed by finite elements analysis and experiment. In [14] and [15], the model of stator faults of permanent magnet synchronous generator is established, and the auto stator fault diagnosis of permanent magnet synchronous generator is realized by ANN.…”
Section: Introductionmentioning
confidence: 99%