2019
DOI: 10.1016/j.cemconres.2018.10.003
|View full text |Cite
|
Sign up to set email alerts
|

Comparative study of two PCE superplasticizers with varied charge density in Portland cement and sulfoaluminate cement systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
36
0
1

Year Published

2019
2019
2022
2022

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 98 publications
(39 citation statements)
references
References 66 publications
2
36
0
1
Order By: Relevance
“…36 specimens for BSEM) were put into a 100 g cold isopropanol (5°C) bath to terminate cement hydration and then sample was dried under nitrogen flow at atmospheric pressure. 38…”
Section: Test Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…36 specimens for BSEM) were put into a 100 g cold isopropanol (5°C) bath to terminate cement hydration and then sample was dried under nitrogen flow at atmospheric pressure. 38…”
Section: Test Methodsmentioning
confidence: 99%
“…In this study, the solvent exchange method with isopropanol was used to arrest hydration of cement . Samples (1g powder or fresh paste for XRD and TG or 0.5g cube specimens for BSEM) were put into a 100 g cold isopropanol (5°C) bath to terminate cement hydration and then sample was dried under nitrogen flow at atmospheric pressure …”
Section: Experimental Programmentioning
confidence: 99%
“…The zeta potential is highly sensitive to the chemical composition of the solvent such as ionic species, pH, and conductivity [23,24]. Many zeta potential measurements have been performed on cement particles [19][20][21][25][26][27][28][29][30][31]; measurements have been performed on OPCs, BFSCs [19,21,26,31], hydrated materials [20,25,28,29], and minerals for admixture [27,30]. Nevertheless, the data for UFC used in this study were not reported.…”
Section: Measurement Of Zeta Potentialmentioning
confidence: 99%
“…Nevertheless, the data for UFC used in this study were not reported. In addition, there are some cases wherein SPs were added to the system [28][29][30][31]; however, these were measured using an electroacoustic method in high-concentration systems [28][29][30] or different conditions of solution even in the case of diluted systems [31]. Therefore, it was necessary to measure the zeta potential under the conditions established in this experiment.…”
Section: Measurement Of Zeta Potentialmentioning
confidence: 99%
“…Therefore, the reason why the poly-phosphate could effectively enhance the dispersion, whilst the mono-phosphate failed cannot be simply explained by the retarding effect. One possible explanation might be attributed to the difference in the molecular structure of the phosphates, which could result in different performance at the water/solid interface during the very early-stage hydration [39][40][41][42], and this would further influence the adsorption layer [43][44][45]. As a consequence, the difference in PCE adsorption behavior could be expected in the presence of different phosphates.In this study, the dispersion mechanism of the PCE-phosphate system was investigated.…”
mentioning
confidence: 99%