2016
DOI: 10.1155/2016/2828647
|View full text |Cite
|
Sign up to set email alerts
|

Comparative Study of Novel Ratio Spectra and Isoabsorptive Point Based Spectrophotometric Methods: Application on a Binary Mixture of Ascorbic Acid and Rutin

Abstract: This paper presents novel methods for spectrophotometric determination of ascorbic acid (AA) in presence of rutin (RU) (coformulated drug) in their combined pharmaceutical formulation. The seven methods are ratio difference (RD), isoabsorptive_RD (Iso_RD), amplitude summation (A_Sum), isoabsorptive point, first derivative of the ratio spectra (1DD), mean centering (MCN), and ratio subtraction (RS). On the other hand, RU was determined directly by measuring the absorbance at 358 nm in addition to the two novel … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
3
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 23 publications
(19 reference statements)
0
3
0
Order By: Relevance
“…Calibration curve was put up for CXB by making use of amplitude difference of attained ratio spectra at 241 and 257 nm; for TMD, amplitude difference of attained ratio spectra at 220 and 237 nm against concentrations were plotted and the regression equations were computed. 12,[40][41][42][43][44][45][46]…”
Section: Ratio Difference Spectroscopic Methods (Rd)mentioning
confidence: 99%
“…Calibration curve was put up for CXB by making use of amplitude difference of attained ratio spectra at 241 and 257 nm; for TMD, amplitude difference of attained ratio spectra at 220 and 237 nm against concentrations were plotted and the regression equations were computed. 12,[40][41][42][43][44][45][46]…”
Section: Ratio Difference Spectroscopic Methods (Rd)mentioning
confidence: 99%
“…Further, a calibration curve was plotted using amplitude difference against concentration. [33][34][35][36][37][38][39] Derivative Ratio Spectrum-Zero crossing Method (DRZC)…”
Section: Ratio Difference Spectroscopic Methods (Rds)mentioning
confidence: 99%
“…Three different concentrations of the analytes (80%, 100%, and 120%) were prepared, each containing 70% of the analyte and 30% of the standard. This approach helps verify whether the method can accurately measure the true value of the analyte concentrations [19,20].…”
Section: B Accuracymentioning
confidence: 99%