2008
DOI: 10.1016/j.jvir.2008.07.014
|View full text |Cite
|
Sign up to set email alerts
|

Comparative Study of Four Different Spherical Embolic Particles in an Animal Model: A Morphologic and Histologic Evaluation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
29
0

Year Published

2009
2009
2019
2019

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 55 publications
(32 citation statements)
references
References 29 publications
3
29
0
Order By: Relevance
“…13 Another frequent reason for recanalization is extravasation of the embolic material due to vessel wall destruction. This mechanism has been described in previous reports, including embolization of human AVMs with cyanoacrylates 25 or polyvinyl alcohol particles, 26 and embolization of the animal kidney 14,27 or uterus 20 with polyvinyl alcohol particles and various microspheres. Because no vessel wall damage was observed in our study, this also contributes to the observed results.…”
Section: Recanalizationmentioning
confidence: 54%
See 1 more Smart Citation
“…13 Another frequent reason for recanalization is extravasation of the embolic material due to vessel wall destruction. This mechanism has been described in previous reports, including embolization of human AVMs with cyanoacrylates 25 or polyvinyl alcohol particles, 26 and embolization of the animal kidney 14,27 or uterus 20 with polyvinyl alcohol particles and various microspheres. Because no vessel wall damage was observed in our study, this also contributes to the observed results.…”
Section: Recanalizationmentioning
confidence: 54%
“…Because no signs of bacterial colonization were noted, the intraluminal and perivascular inflammation might be due to the toxic effects of ischemia and the embolic material itself. 15,27 In our experiment, the inflammatory changes may partly result from the ischemic effect of the embolization of the kidney that has a terminal circulation without collateral vascular supply. Embolization could produce an ischemic necrosis of kidney tissue that induced various degrees of inflammation reactions trying to "clean" the damaged tissue.…”
Section: Inflammation Reactionsmentioning
confidence: 74%
“…The localized tissue distribution observed with this product, coupled with its in situ degradation and absorption, suggests that OCL 503 may have a greater safety profile than many approved and marketed embolic devices, which can migrate to nontarget tissue or have been reported to extravasate from the target vasculature [3,14,15]. Additional work is warranted with this device.…”
Section: Discussionmentioning
confidence: 94%
“…22 With new materials, such as acrylic embospheres and hepaspheres continuously, emerging the preferred agents are likely to change over time. 23 The advantage of a surgical approach includes complete resection of the disease and pathologic analysis of the specimen to confirm the diagnosis. Where imaging strongly supports a diagnosis of AML, surgical treatment with simple enucleation is feasible and may reduce nephron loss.…”
Section: Discussionmentioning
confidence: 99%