2023
DOI: 10.1016/j.bjane.2021.02.063
|View full text |Cite
|
Sign up to set email alerts
|

Comparative study between suprasternal and apical windows: a user-friendly cardiac output measurement for the anesthesiologist

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 27 publications
0
2
0
Order By: Relevance
“…Recent studies have shown that echocardiographic measurements of aortic flow velocities via the suprasternal view could allow for improved access with high precision and have been shown to be easy to apply even for inexperienced operators. 12 Furthermore, if flow is measured in the descending aorta from the suprasternal view, it has the additional benefit of minimizing the Doppler angle error and potentially improving the accuracy further. 13 We, therefore, aimed to study a novel approach of predicting fluid responsiveness in children intraoperatively, in which the suprasternal notch window is used to measure respiratory variations in peak descending aortic flow (ΔVpeak dAo) with two-dimensional echocardiography.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Recent studies have shown that echocardiographic measurements of aortic flow velocities via the suprasternal view could allow for improved access with high precision and have been shown to be easy to apply even for inexperienced operators. 12 Furthermore, if flow is measured in the descending aorta from the suprasternal view, it has the additional benefit of minimizing the Doppler angle error and potentially improving the accuracy further. 13 We, therefore, aimed to study a novel approach of predicting fluid responsiveness in children intraoperatively, in which the suprasternal notch window is used to measure respiratory variations in peak descending aortic flow (ΔVpeak dAo) with two-dimensional echocardiography.…”
Section: Introductionmentioning
confidence: 99%
“…TTE, although being less invasive, carries the drawback of limited access to the anterior chest wall. Recent studies have shown that echocardiographic measurements of aortic flow velocities via the suprasternal view could allow for improved access with high precision and have been shown to be easy to apply even for inexperienced operators 12 . Furthermore, if flow is measured in the descending aorta from the suprasternal view, it has the additional benefit of minimizing the Doppler angle error and potentially improving the accuracy further 13 .…”
Section: Introductionmentioning
confidence: 99%