2022
DOI: 10.1111/os.13618
|View full text |Cite
|
Sign up to set email alerts
|

Comparative Study between Caspar Cervical Retractor System and Traditional S Retractor in Application on Anterior Cervical Decompression and Fixation

Abstract: Objective Although Caspar cervical retractor system (CCRS) is commonly utilized in anterior cervical decompression and fixation (ACDF), most urban hospitals still use both traditional S retractor and CCRS in conventional anterior cervical surgeries. Related data to evaluate the effect are required to be reported. The aim of this study is to compare the efficacy between using the traditional cervical S retractor and CCRS in anterior cervical decompression and fixation ACDF. Methods The retrospective study that … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 33 publications
(63 reference statements)
0
2
0
Order By: Relevance
“…Third, a Caspar distractor can be used as a supplementary way to achieve intraoperative cervical alignment adjustment. However, the Caspar distractor plays a limited role in cervical alignment correction, particularly in patients with osteoporosis 40,41 . Fourth, although there is still no precise target angle that should be corrected, fluoroscopy should be employed to avoid over‐distraction of the facet joint and anterior intervertebral disc height, as doing so would lead to posterior neck pain and disability 34,42,43 .…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Third, a Caspar distractor can be used as a supplementary way to achieve intraoperative cervical alignment adjustment. However, the Caspar distractor plays a limited role in cervical alignment correction, particularly in patients with osteoporosis 40,41 . Fourth, although there is still no precise target angle that should be corrected, fluoroscopy should be employed to avoid over‐distraction of the facet joint and anterior intervertebral disc height, as doing so would lead to posterior neck pain and disability 34,42,43 .…”
Section: Discussionmentioning
confidence: 99%
“…However, the Caspar distractor plays a limited role in cervical alignment correction, particularly in patients with osteoporosis. 40 , 41 Fourth, although there is still no precise target angle that should be corrected, fluoroscopy should be employed to avoid over‐distraction of the facet joint and anterior intervertebral disc height, as doing so would lead to posterior neck pain and disability. 34 , 42 , 43 According to Bai et al ., an intervertebral height change of >10% leads to post‐operative axial pain.…”
Section: Discussionmentioning
confidence: 99%