2019 International Symposium on Recent Advances in Electrical Engineering (RAEE) 2019
DOI: 10.1109/raee.2019.8886946
|View full text |Cite
|
Sign up to set email alerts
|

Comparative Study Between C-Core/E-Core SFPMM with Consequent Pole SFPMM

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
6
2

Relationship

5
3

Authors

Journals

citations
Cited by 10 publications
(10 citation statements)
references
References 12 publications
0
10
0
Order By: Relevance
“…For different values of k, various rotor pole and stator slot such as Z s /Z r =12/8, 12/9, 12/10, 12/11, 12/13, 12/14, 12/15, 12/16, and 12/17 are developed, simulated and analyzed under 2-D FEA. Based on no-test and on-load conditions, designs with that Z s /Z r =12/11, 12/13, and 12/17, are capable of producing sinusoidal open-circuit phase flux linkage and uni-directional instantaneous torque [10][11] . Therefore, aforesaid three rotor poles are proceeded to rotor structure.…”
Section: Combination Of Stator Slot and Rotor Polesmentioning
confidence: 99%
“…For different values of k, various rotor pole and stator slot such as Z s /Z r =12/8, 12/9, 12/10, 12/11, 12/13, 12/14, 12/15, 12/16, and 12/17 are developed, simulated and analyzed under 2-D FEA. Based on no-test and on-load conditions, designs with that Z s /Z r =12/11, 12/13, and 12/17, are capable of producing sinusoidal open-circuit phase flux linkage and uni-directional instantaneous torque [10][11] . Therefore, aforesaid three rotor poles are proceeded to rotor structure.…”
Section: Combination Of Stator Slot and Rotor Polesmentioning
confidence: 99%
“…Aforementioned designs are taken for validation purpose of the proposed design. Moreover, the proposed 12S‐13P E‐Core PMCPFSM is investigated in [1, 16, 24] and are considered here just for comparison with the new reduced 6S‐13P PMCPFSM.…”
Section: Electromagnetic Performance Analysis Of Initial Design Opmentioning
confidence: 99%
“…Moreover, FEA requires expensive software/hardware and large drive due to repeated iteration [11]. Therefore, author [1, 15, 16] suggest alternate analytical model for initial design phase.…”
Section: Introductionmentioning
confidence: 99%
“…Despite of high PM usage, the narrow flux bridge saturates and provide short path to flux which upsurge flux circulation and cancellation that results an increase cogging torque, torque ripples, low torque density and power density and degrade electromagnetic performance. Concerning the PM usage, author in [9,10] reviewed reduce PM topologies PMFSMs, author in [11] introduces different E-Core and C-Core whereas comprehensive comparison is investigated in [12,13]. However, reduce PM topologies with C-Core and E-Core still suffer from stator leakage flux (as shown in Fig.…”
Section: Introductionmentioning
confidence: 99%