Comparative Strain Gauge Analysis of External and Internal Hexagon, Morse Taper, and Influence of Straight and Offset Implant Configuration

Abstract: The results showed fundamental differences in both conditions. There was no evidence that there was any advantage to offset implant placement in reducing the strain around implants. The results also revealed that the internal hexagon and Morse taper joints did not reduce the microstrain around implants.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
63
2
4

Year Published

2013
2013
2018
2018

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 49 publications
(72 citation statements)
references
References 17 publications
2
63
2
4
Order By: Relevance
“…One thousand units of microstrain (1000 µε) correspond to the stretching or compression of 0.1% of the structure in question. 33,34 Nishioka et al 28 emphasizes that the CoCr alloy has been increasingly used in supported fixed dental prosthesis and supported implants for its high corrosion resistance, which ensures its biocompatibility.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…One thousand units of microstrain (1000 µε) correspond to the stretching or compression of 0.1% of the structure in question. 33,34 Nishioka et al 28 emphasizes that the CoCr alloy has been increasingly used in supported fixed dental prosthesis and supported implants for its high corrosion resistance, which ensures its biocompatibility.…”
Section: Discussionmentioning
confidence: 99%
“…10,23,24,28,35 In his study, Goll 35 recommends a clinical protocol to be followed when making prosthetic implants. One of the recommendations for measures to avoid mismatch of the prosthetic implant is casting in a single block.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Alguns trabalhos utilizam dispositivos especiais de aplicação de carga 6 e outros empregam máquinas de ensaio universal 17,18 . O presente estudo utilizou o dispositivo de aplicação de carga (DAC), de acordo com estudos relatados na literatura que utilizaram esse dispositivo para aplicação de cargas estáticas axiais e não axiais 10,11,13 .…”
Section: Discussionunclassified
“…Diferentes estudos in vitro, utilizando-se a técnica de extensometria e o poliuretano para simulação da estrutura óssea, verificaram o comportamento biomecânico em diferentes posições dos implantes e também em diferentes componentes para prótese sobre implantes [8][9][10] . A extensometria linear elétrica é uma proposta concreta para avaliar a distribuição de cargas estáticas ao redor de implantes [10][11][12] .…”
Section: Introductionunclassified