2003
DOI: 10.1002/chir.10260
|View full text |Cite
|
Sign up to set email alerts
|

Comparative performances of selected chiral HPLC, SFC, and CE systems with a chemically diverse sample set

Abstract: Pharmaceutical companies have a continuous need to resolve new racemates. Analysis may be required in aqueous and nonaqueous media, or in the presence of several different sets of potentially interfering compounds. There is often a preparative requirement. For these reasons analysts may require a number of different separation systems capable of resolving a given pair of enantiomers. We wished to improve upon existing approaches that address this situation and undertook a program of work to screen over 100 rac… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
25
1
1

Year Published

2004
2004
2020
2020

Publication Types

Select...
5
5

Relationship

0
10

Authors

Journals

citations
Cited by 39 publications
(29 citation statements)
references
References 37 publications
(25 reference statements)
2
25
1
1
Order By: Relevance
“…SFC and CE offer potential advantages vis-à-vis HPLC and complement one another in terms of solubility options [1]. Although progress continues to be made in nonaqueous chiral CE [2,3], aqueous CE dominates the field of chiral CE analysis.…”
Section: Pha-543613 N-(3r)-1-azabicyclo[222]oct-3-ylfuro[23-c]-mentioning
confidence: 99%
“…SFC and CE offer potential advantages vis-à-vis HPLC and complement one another in terms of solubility options [1]. Although progress continues to be made in nonaqueous chiral CE [2,3], aqueous CE dominates the field of chiral CE analysis.…”
Section: Pha-543613 N-(3r)-1-azabicyclo[222]oct-3-ylfuro[23-c]-mentioning
confidence: 99%
“…As pointed out above, the 2-APAs are frequently used as "typical" acidic pharmaceuticals for an evaluation of novel separation techniques and/or approaches to enan-tiomeric resolution [88][89][90][91][92][93] and are included in compilations of resolutions using a variety of selectors [94]. It is therefore difficult to ensure that all the reported methodologies are covered in this review.…”
Section: Enantiomeric Resolution and Analysis Of 2-apa Nsaidsmentioning
confidence: 99%
“…[24] using a test set of 102 chiral molecules. More than 100 different systems were tested to evaluate the performance of the techniques.…”
Section: Separations On Polysaccharide-based Cspmentioning
confidence: 99%