2020
DOI: 10.1007/s11306-020-1650-y
|View full text |Cite
|
Sign up to set email alerts
|

Comparative lipidomic analysis of inflammatory mediators in the aqueous humor and tear fluid of humans and rabbits

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
11
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 9 publications
(12 citation statements)
references
References 62 publications
1
11
0
Order By: Relevance
“…Then, the sample was loaded, and the cartridge was washed with 2 mL of 15% methanol containing 0.1% formic acid, after which the lipids were sequentially eluted with 500 µL of anhydrous methanol and 500 µL of acetonitrile. The resulting samples were concentrated by evaporation of the solvent under a gentle stream of nitrogen and stored at −80 • C. For the identification of lipid mediators, the respective lipid extracts were analyzed using an 8040 series UPLC-MS/MS mass spectrometer (Shimadzu, Japan) in multiple-reaction monitoring mode at a unit mass resolution for both the precursor and product ions [46]. The selected molecular ions were fragmentized in the gas phase by collision-induced dissociation and analyzed by tandem (MS/MS) mass spectrometry.…”
Section: Uplc-ms/ms Conditions and Sample Preparationmentioning
confidence: 99%
“…Then, the sample was loaded, and the cartridge was washed with 2 mL of 15% methanol containing 0.1% formic acid, after which the lipids were sequentially eluted with 500 µL of anhydrous methanol and 500 µL of acetonitrile. The resulting samples were concentrated by evaporation of the solvent under a gentle stream of nitrogen and stored at −80 • C. For the identification of lipid mediators, the respective lipid extracts were analyzed using an 8040 series UPLC-MS/MS mass spectrometer (Shimadzu, Japan) in multiple-reaction monitoring mode at a unit mass resolution for both the precursor and product ions [46]. The selected molecular ions were fragmentized in the gas phase by collision-induced dissociation and analyzed by tandem (MS/MS) mass spectrometry.…”
Section: Uplc-ms/ms Conditions and Sample Preparationmentioning
confidence: 99%
“…The extraction of lipids for UPLC-MS/MS analysis was performed exactly as described in our resent study [29]. Briefly, TF samples were mixed with 2 ng of deuterated internal standard solutions and centrifuged (12,000× g, 3 min).…”
Section: Lipid Extractionmentioning
confidence: 99%
“…TF lipids were analyzed in the obtained extracts using 8040 series UPLC-MS/MS mass spectrometer (Shimadzu, Japan) in multiple-reaction monitoring mode at a unit mass resolution for both the precursor and product ions [29,35]. The lipids separation was performed by reverse-phase UPLC on Phenomenex C8 column (0.4 mL/min, sample temperature of 5 • C).…”
Section: Uplc-ms/ms Analysismentioning
confidence: 99%
See 2 more Smart Citations