2021
DOI: 10.1002/acm2.13245
|View full text |Cite
|
Sign up to set email alerts
|

Comparative dosimetry of radiography device, MSCT device and two CBCT devices in the elbow region

Abstract: The aim of the study was to estimate and to compare effective doses in the elbow region resulting from four different x-ray imaging modalities. Absorbed organ doses were measured using 11 metal oxide field effect transistor (MOSFET) dosimeters that were placed in a custom-made anthropomorphic elbow RANDO phantom.Examinations were performed using Shimadzu FH-21 HR radiography device, Siemens Sensation Open 24-slice MSCT-device, NewTom 5G CBCT device, and Planmed Verity CBCT device, and the effective doses were … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
0
0
2

Year Published

2022
2022
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 47 publications
(79 reference statements)
0
0
0
2
Order By: Relevance
“…Нередко стандартной рентгенографии недостаточно для постановки правильного диагноза и планирования лечения [21]. В целях дообследования врачи-травматологи назначают МСКТ, при проведении которой пациент укладывается в позе «супермена» с вытянутой рукой в гентри [22,23]. Однако в случаях вынужденной иммобилизации или выраженного болевого синдрома у больного приходится производить атипичную укладку пациента [23].…”
Section: результаты и обсуждениеunclassified
See 1 more Smart Citation
“…Нередко стандартной рентгенографии недостаточно для постановки правильного диагноза и планирования лечения [21]. В целях дообследования врачи-травматологи назначают МСКТ, при проведении которой пациент укладывается в позе «супермена» с вытянутой рукой в гентри [22,23]. Однако в случаях вынужденной иммобилизации или выраженного болевого синдрома у больного приходится производить атипичную укладку пациента [23].…”
Section: результаты и обсуждениеunclassified
“…В основу их работы вошло сравнение доз МСКТ и КЛКТ, полученных в ходе исследования антропоморфного фантома руки взрослого человека. В результате лучевая нагрузка у КЛКТ составила 2,0-6,7 мкЗв, а у МСКТ -37,4 мкЗв [22].…”
Section: Indicators Of Diagnostic Accuracy Of Cbct Presented In Scien...unclassified
“…The effective radiation dose required for a CBCT scan can be as low as that for a panoramic dental Xray and less than that for a medical CT scan. Koivisto et al 30 and Weiss and Reid-Fuller 31 stated that the effective dose for CBCT varies depending on the device but is typically less than the doses reported for medical CT scans. It should be noted, however, that the presence of artefacts on CBCT sometimes makes interpretation of the images difficult.…”
Section: Original Research Articlementioning
confidence: 99%
“…There cities. The dose-related drawback is even more relevant for MSCT (Koivisto et al, 2021), which explains the reduced use of this imaging modality in implant dentistry in the past years (i.e., less than 10 studies on the topic over the last decade). Adding to that, both CBCT and MSCT significantly impact on the final costs of the treatment, and this aspect must be taken into consideration for both the private and the public healthcare sectors (Petersen et al, 2015).…”
Section: Can We Tailor Digital Diagnostic Imaging To Optimise the Gen...mentioning
confidence: 99%