2019
DOI: 10.1016/j.buildenv.2019.106271
|View full text |Cite
|
Sign up to set email alerts
|

Comparative bioclimatic approach for comfort and passive heating and cooling strategies in Algeria

Abstract: A B S T R A C TThe energy consumption and thermal comfort in buildings are heavily affected by weather conditions. Therefore, the aim of this paper is to analyze the bioclimatic potential of Algerian climate zones. This analysis was made based on eight representative locations using recent weather datasets (2003)(2004)(2005)(2006)(2007)(2008)(2009)(2010)(2011)(2012)(2013)(2014)(2015)(2016)(2017). The thermal comfort and passive design potential analysis were based on a psychometric chart applying the adaptive … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
30
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
8
1

Relationship

3
6

Authors

Journals

citations
Cited by 49 publications
(39 citation statements)
references
References 34 publications
(50 reference statements)
0
30
0
Order By: Relevance
“…The MBE is a nondimensional measure of the overall bias error between the measured and simulated data with a known time resolution. The (RMSE) indicates how well the simulation model describes the variability in the measured data [53]. Moreover, for the validation step, simulation was run for 48 h because we considered this a sufficient duration for the model's validation (Figure 5) and (Table 4).…”
Section: (C) Validation Of Envi-met Measurement Versus Simulationmentioning
confidence: 99%
See 1 more Smart Citation
“…The MBE is a nondimensional measure of the overall bias error between the measured and simulated data with a known time resolution. The (RMSE) indicates how well the simulation model describes the variability in the measured data [53]. Moreover, for the validation step, simulation was run for 48 h because we considered this a sufficient duration for the model's validation (Figure 5) and (Table 4).…”
Section: (C) Validation Of Envi-met Measurement Versus Simulationmentioning
confidence: 99%
“…We simulate the three models based on the Typical Meteorological Year (TMY) files with Epw format: TMY2 (1981-1990), TMY3 (1991-2005) taken from Meteonorm 7.2 database (https://meteonorm.com/en/ accessed on 20 August 2020) [55], and TMYx (2003-2017) (Figure 6). The last meteorological file is taken from http://climate.onebuilding.org/ (accessed on 20 August 2020) [56], which is validated by the study of Semahi et al [53] and shows a high-quality.…”
Section: Assessment Of the Outdoor Thermal Comfort With Pet Indexmentioning
confidence: 99%
“…The indoor air temperature of the simulated model was compared with the monitored indoor air temperature. The basecase model was then calibrated using two equations of normalised mean bias error (NMBE) and coefficient of variation of root square mean error (CV-RMSE), which are reliable measures for the validation of calibration [46][47][48]. The calibration was further validated using linear regression analysis to graphically represent the accuracy and correlation between simulated and monitored data.…”
Section: Simulation Of the Basecase Modelmentioning
confidence: 99%
“…The authors are aware that behavioral and psychological adaptations have proven to have a remarkable impact on thermal perception [44]. This approach can add several recommendations for developing an adaptive urban oasis model and bioclimatic design recommendations in oasis zone of Algeria [45].…”
Section: Implication On Practice and Researchmentioning
confidence: 99%