2023
DOI: 10.3390/ma16041625
|View full text |Cite
|
Sign up to set email alerts
|

Comparative Analysis of Waste, Steel, and Polypropylene Microfibers as an Additive for Cement Mortar

Abstract: This study presents the results of laboratory experiments conducted to determine the mechanical parameters for cement mortar with various quantities of waste fibers, polypropylene microfibers, and steel microfibers. Waste fibers were used as samples and obtained using an end-of-life car tire recycling process. For comparison, samples with the addition of steel and polypropylene microfibers were tested. The same degrees of fiber reinforcement were used for all types of fibers. Ultimately, 22 mixtures of cement … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3
1
1

Relationship

2
3

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 53 publications
(60 reference statements)
0
4
0
Order By: Relevance
“…Steel cords differ in terms of the length and diameter of their fibers, due to the various types and sizes of tires (Figure 2). Steel cord specifications were determined in previous studies [7,9,10] Portland cement CEM I 42,5 R was used in amounts of 400 kg/m³. Superplasticizer Silka ViscoCrete 5-600 was applied in amounts of 1% of cement weight.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Steel cords differ in terms of the length and diameter of their fibers, due to the various types and sizes of tires (Figure 2). Steel cord specifications were determined in previous studies [7,9,10] Portland cement CEM I 42,5 R was used in amounts of 400 kg/m³. Superplasticizer Silka ViscoCrete 5-600 was applied in amounts of 1% of cement weight.…”
Section: Methodsmentioning
confidence: 99%
“…Steel cords differ in terms of the length and diameter of their fibers, due to the various types and sizes of tires (Figure 2). Steel cord specifications were determined in previous studies [7,9,10]. A total of 8 mixtures, which differed in terms of the aggregate used, were tested.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Note, the steel cord lengths and fiber diameters varied due to the different types and sizes of tires. Steel cord specifications were determined in previous studies [21,30,31]. See Table 1 and Fig.…”
Section: Materials and Specimensmentioning
confidence: 99%