2015
DOI: 10.1016/j.ijheatmasstransfer.2015.04.072
|View full text |Cite
|
Sign up to set email alerts
|

Comparative analysis of the cross-flow indirect evaporative air coolers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
4
0
1

Year Published

2015
2015
2018
2018

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 40 publications
(8 citation statements)
references
References 37 publications
1
4
0
1
Order By: Relevance
“…It can be observed in Figure 6 (a2, b2, c2, d2) that the inlet temperature of the working air in the wet channel is equal to the air temperature leaving the working air-dry channels. Such a behavior of the temperature distribution of the wet air was also reported by Bolotin et al [47] for a cross-flow HMX. For wet air channel 1 (using water), the working air enters at a temperature of 34.3 • C and attain its wet bulb temperature (21.8 • C) at a channel width ratio of 70%.…”
Section: Heat and Mass Transfer Characteristics Of The Hmxsupporting
confidence: 83%
“…It can be observed in Figure 6 (a2, b2, c2, d2) that the inlet temperature of the working air in the wet channel is equal to the air temperature leaving the working air-dry channels. Such a behavior of the temperature distribution of the wet air was also reported by Bolotin et al [47] for a cross-flow HMX. For wet air channel 1 (using water), the working air enters at a temperature of 34.3 • C and attain its wet bulb temperature (21.8 • C) at a channel width ratio of 70%.…”
Section: Heat and Mass Transfer Characteristics Of The Hmxsupporting
confidence: 83%
“…Secondary air inlet conditions T s,in,HE and X s,in,HE are calculated from the saturation efficiency defined in Eq. (10). As shown in detail in Section 4.3, values of ε h of the investigated indirect evaporative cooling system strongly depend on the secondary air inlet conditions and on the water flow rate.…”
Section: Secondary Air Saturation Efficiencymentioning
confidence: 87%
“…Stoitchkov and Dimitrov [8] developed a short-cut method for calculating the effectiveness of a cross-flow IEC, introducing a correction to the Maclaine-cross and Banks' model [9]. Bolotin et al [10] presented an -NTU analysis of two different…”
Section: Introductionmentioning
confidence: 99%
“…Для ефективності збільшення повітряного охолодження запропоновано враховувати атмосферні фактори в умовах жаркого та сухого клімату з встановленням спеціального випаровуючого осушувача [2], або за умови різних значень відносної вологості та зміни вартості на гідрофільні матеріали [3]. Іншими шляхом є пошук методу для вирішення задачі математичного моделювання, в якій пропонується виконувати порівняння типового повітряного холодильника з рекуперативним, без застосування експериментальних дослідів, але після попереднього визначення переважних умов роботи [4], чисельне моделювання теплообмінних апаратів незалежно від пори роки, в якій працює відбувається робочий процес [5]. Проблему підвищення ефективності використання повітряних холодильників пропонується вирішувати також за рахунок застосування нових композитних матеріалів з удосконаленими характеристиками [6], та з обов'язковим врахуванням робочого середовища теплообмінних апаратів з допустимими технологічними параметрами [7].…”
Section: аналіз літературних даних та постановка проблемиunclassified