2019
DOI: 10.1016/j.oftal.2018.11.014
|View full text |Cite
|
Sign up to set email alerts
|

Comparación de medidas de poder dióptrico corneal y astigmatismo entre un topógrafo basado en tecnología de diodo-emisor de luz a color (Cassini®) y un topógrafo basado en tecnología Scheimpflug (Pentacam®)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2020
2020
2021
2021

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 28 publications
0
2
0
Order By: Relevance
“…The Cassini system has been shown to determine consistent measures of posterior corneal curvature and astigmatism in healthy eyes, but only measures of posterior astigmatism could be considered as interchangeable with those provided by the Pentacam [40]. In another study, for the astigmatism analysis, measurements from the anterior cornea obtained with color-LED topography showed an excellent agreement with Pentacam measurements, but the agreement was poor for the corneal posterior surface and particularly the magnitude of astigmatism [41,42]. Furthermore, when analyzing corneal aberrometry measurements obtained with the Cassini device in healthy eyes, they were not interchangeable with results provided by the Scheimpflug-based topography [43].…”
Section: Color Light-emitting Diodementioning
confidence: 99%
See 1 more Smart Citation
“…The Cassini system has been shown to determine consistent measures of posterior corneal curvature and astigmatism in healthy eyes, but only measures of posterior astigmatism could be considered as interchangeable with those provided by the Pentacam [40]. In another study, for the astigmatism analysis, measurements from the anterior cornea obtained with color-LED topography showed an excellent agreement with Pentacam measurements, but the agreement was poor for the corneal posterior surface and particularly the magnitude of astigmatism [41,42]. Furthermore, when analyzing corneal aberrometry measurements obtained with the Cassini device in healthy eyes, they were not interchangeable with results provided by the Scheimpflug-based topography [43].…”
Section: Color Light-emitting Diodementioning
confidence: 99%
“…Although corneal topography and tomography are widely used, it is common that these technologies are confused [4,6,41,[80][81][82][83][84]. This corrigendum could be associated with the fact that at the time when corneal tomographers were developed, the nomenclature was not yet defined [8].…”
Section: Confusion In Terminologymentioning
confidence: 99%