2012
DOI: 10.1109/tcpmt.2012.2198885
|View full text |Cite
|
Sign up to set email alerts
|

Compact Thermal Resistor-Capacitor-Network Approach to Predicting Transient Junction Temperatures of a Power Amplifier Module

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
17
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 47 publications
(17 citation statements)
references
References 24 publications
0
17
0
Order By: Relevance
“…For each subset, an optimized model code can be obtained, and then a complete model code can be pieced together by summing the exponential terms in a closed form of the simple analytical expression [38]:…”
Section: A Derivation Of the Thermal Modelmentioning
confidence: 99%
See 1 more Smart Citation
“…For each subset, an optimized model code can be obtained, and then a complete model code can be pieced together by summing the exponential terms in a closed form of the simple analytical expression [38]:…”
Section: A Derivation Of the Thermal Modelmentioning
confidence: 99%
“…In the literature, a trend is to move towards real-time power device junction temperature estimation [2]- [5] based on certain thermal models. Typical models of a single-chip power module are in the form of either Cauer network [6] [7] or Foster network [8] [9], as shown in Fig. 1.…”
Section: Introductionmentioning
confidence: 99%
“…The heating/ cooling table is a simplified model of the temperature transient response. Single stage lumped model for temperature transient response T i of component i at time t can be simplified as follows [5]:…”
Section: Framework Of Stammentioning
confidence: 99%
“…Compact thermal models expressed as thermal resistorcapacitor (RC) networks were more widely employed to rapidly predict junction temperatures or the temperatures at a few critical locations in the power modules for electro-thermal design, thermal management, reliability and lifetime prediction [15][16][17][18][19][20][21][22][23][24]. In the simplified cases, individual power device might be considered and one dimensional heat conduction was assumed to predict the junction temperatures [23][24][25].…”
Section: Introductionmentioning
confidence: 99%
“…In the simplified cases, individual power device might be considered and one dimensional heat conduction was assumed to predict the junction temperatures [23][24][25]. The models were constructed using either Cauer cells or Foster cells, while mathematic methods have been developed and well Jianfeng known to transform these two network models from each other [24][25][26].…”
Section: Introductionmentioning
confidence: 99%